How to assess the selection and continuation of rfid source electronic label module
Where should we start to assess the source RFID label selection and continuation?
The answer is put out: the selection looks at three things - frequency/agreement, interface and containment, launch power and reception sensitivity; the continuation of the flight looks at the ratio of battery capacity to working currents, then calculates the real life of the actual launch cycle.
The most significant difference between the source RFID labels (sourced electronic tags) and non-existent, is that it has built a battery, which sends a signal out of its own way. The advantage is that it can read distance (usually 30 to 100 metres or more), has a strong resistance; the cost is that the battery has life, and it will be changed in a few years. These two characteristics determine the typical scenario: large asset management, vehicle tracking, location of mine personnel, container logistics, farm tracers, etc.
Select the first step: determine frequency and protocol
The frequency of work in the country is 433 MHz, 915 MHz (UHF-band), 2.45GHz (microwave segment), and a few scenarios are 125 kHz. The higher the frequency, the faster the transmission rate, but the less the ability to bypass the barrier, the more pronounced the rain or metal environment decays.
In terms of protocols, if your reader is part of the existing system, you give priority to agreements that are compatible with it, such as ISO/IEC 18000 series and some private agreements between manufacturers. The protocol does not match, the reader does not recognize labels, and multiple parameters are white.
433 MHz is suitable for ultra-distance, simple barrier scenarios such as open site vehicle identification; 2.4GHz is appropriate for high data throughput, and anti-disturbing high-demand plant workshops; 915 MHz is in between, which is a relatively large frequency range of logistics storage.
Step 2 in equipment selection: Check the key values in the hardware specifications
The parameters are so secretive, but you just have to keep an eye on them:
- Launch power.: Directly determines how far it can be passed. The greater the power, the faster the power, the faster the electricity. Usually between 0 dBm and 30 dBm (dBm is a unit of power in wireless communications, 0 is 1 mW, 30 equals about 1 W).
- Receiving sensitivity: The more negative the value, for example -95 dBm is more sensitive than -85 dBm. High sensitivity means that weak signals from remote return are also recognized by readers.
- Work and hibernation currents: Work current means power consumption in the immediate launch (several millimetres to tens of milli an) and dormant current (micro-grade) is the bottom line for maintaining circuit operation in the event of no incident.
- Launch period or interval reported: The frequency of a sign sent by the label, for example, once per second and every minute. This number has the greatest impact on the continuation of the voyage.
- Encapsulated LevelIP level (dustproof water-preservation, ISP67 can be immersed in short duration) and work temperature range, which is usually required at industrial sites -40°C to +85°C.
What do we do with the re-entry?
The most common estimation formula:
Battery life ≈ battery capacity (mAh) ÷ [transmit current × transmit duty cycle + sleep current × sleep duty cycle]
Take a 2,400 mAh lithium battery (milliamp-hours measure capacity). The tag transmits once every three seconds, for about 10 ms each time, a duty cycle of roughly 0.3%. It draws 20 mA while transmitting and sleeps the rest of the time at 5 µA. Average current is about 20 × 0.003 + 0.005 ≈ 0.065 mA, for a theoretical life of 2,400 ÷ 0.065 ≈ 37,000 hours, or roughly 4.2 years.
This is an ideal figure. In practice, service life is usually 50%–70% of the theoretical value because of temperature, self-discharge, and battery aging. Below −20°C, lithium battery performance declines considerably, and capacity may drop by half.
The factors that influence the actual continuation of the voyage are far more complex than the parameter table.
The parameter table gives the number of the 25°C laboratory conditions.
- TemperatureThe heat acceleration cell is self-recharged (the battery itself is slowly out of power), and the temperature is reduced by its effective capacity.
- Launched as a percentage of empty: When labels are frequently awakened into the reader area, they are launched much more often than the plant was set out to run and they are used to soar.
- Wireless environmental disturbance: Metal shield, multi-range reflection (a signal is re-reflected and superimposed in space) will allow the label to be re-transmitted, with a successful reading card likely to be re-issued several times.
- Battery quality and consistency: Industrial lithium thionyl chloride batteries, high-capacity batteries suited to long standby, cost three to five times as much as consumer coin cells. Annual self-discharge can be kept below 1%, compared with 5%–10% for ordinary coin cells.
On one cold-chain transport project, the datasheet suggested three years of battery life, but widespread power failures began after only two and a half. The main causes were -15°C temperatures and frequent wake-ups when passing readers. Switching to wide-temperature batteries and lengthening the transmission interval solved the problem.
What tests should be done to evaluate the continuation of the voyage?
It is recommended that at least three validations be made for the lack of a single view of the parameter table:
- The temperature is constant.: Keep the labels launched on a continuous basis, at 25°C, according to the actual cycle, and record the actual hours of power depletion as the baseline.
- High-temperature cycle test: Cycle the tags between -20°C and +60°C in a temperature chamber for one to two months to observe the capacity degradation curve.
- Typical scene validation on site: Apply several dozen tags in an actual operating environment and run them continuously for three to six months. Track the rate of degradation, successful transmissions, and retransmissions.
If the project itself is subject to industry certification (e.g., in the medical and tradable fields), the results of the re-flight test are also a mandatory part of the certification report.
What are the common areas of error in the selection and re-launch assessment?
A few easy pits:
- Just look at the "read-out range of 100 metres" that's on the list, ignoring what is ideal in an empty and unconcealed environment, which may be a trade-off in metal stores.
- The replacement of technical-grade lithium thiomeric chloride batteries with a common button cell (CR2032 equivalent) is initially low, but after one year, the mass failure is higher than maintenance costs.
- Set the launch cycle too close (for example, once a second) on the grounds that "not read or send more than one time" and then light it before a year.
- The purchase was then posted directly, without the site temperature and disturbance assessment, and before the programme was changed when problems arose.
How can an assessment of the selection and renewal be made quickly?
I'll give you a list of the things that can be used:
- The need for the use of scenes and reading distance is specified, with constraints such as temperature, shielding, metal environment etc.
- Locked out the candidate modules for sections 2 to 3, comparing frequency, launch power, reception sensitivity, containment level.
- The scalable formula calculates the theoretical value based on the actual launch cycle and working temperature, with a further discount of 70 per cent as a conservative estimate.
- Small quantities of purchases are measured on-site and run at least one full business cycle.
- Include test data in the selected report, including recommendations for battery replacement cycles and later maintenance.
Shanghai-based Skill and Technology, Inc., has built up more complete data samples in a variety of industry-based active RFID projects, especially the wide temperature cell selection and field decay testing. If you're doing an assessment of the source label option, you can send us scenarios, and check this list with one item less curved way.
And let's sum up: the selection is for the most well-matched module, not the one with the highest amount of parameters; the continuation of the flight is for field measurements, not theoretical numbers. The two things are assessed separately, and then combined to verify, the solution will be basically unproblematic.