Classification of rfid labels: by frequency band, mode of power supply and cover form
Conclusion: RFID labels do not have the "best" classification, only the one that is best for the scene.
The first question that clients ask for in the years of RFID is, "What labels are best," but what really determines how the project works or fails is the frequency of the label, whether the power supply and containment patterns can match the specific scene. The frequency determines distance and environmental resistance, the power supply determines the distance from reading and writing, life and cost structure, and the containment shape determines whether it can carry the physical environment on the site.
By frequency band: LF, HF, HHF, and HHF, supplemented by microwave
The working frequency of the RFID label directly determines its distance, penetration and application, which is the first watershed in the selection.
Low frequency LF (125-134 kHz)
Low-frequency labels are usually within 10 cm of reading and writing distance, signal is not sensitive to metals and water, and can penetrate thin walls without metal material. It's common in animal earmarks, early versions of door-barrier cards, car keys, livestock retroactivity. This is the frequency used in a farm where pigs are traced, and the label is buried in the earmarks, readers close to them, and slaughtering is also identified.
HF (13.56 MHz)
The high frequency tags are usually within 1 metre, and the standard is very standardized, with reference to ISO 14443 and ISO 15693. Daily contact cards, ID cards, library book labels, hotel room cards fall into this category. The advantages of the HF segment are that the protocol is mature, the reader is cheap, the disadvantage is short, it is not suitable for long-range mass reading.
UHF (860-960 MHz)
UHF has been the main industrial RFID band over the past decade. Read/write range can exceed 10 m, and it supports bulk reading of multiple tags. This makes it particularly useful for warehousing, logistics, retail, and production traceability. UHF tags can be thin and inexpensive, but performance falls on metal and liquid surfaces, calling for purpose-built on-metal designs. Frequency use is regulated in China and overseas. China, for example, uses 920–925 MHz and the US uses 902–928 MHz. Plan for band changes in international deployments.
Microwave (2.45 GHz, 5.8 GHz)
Microwave labels are used in a relatively small number of special settings, such as real-time positioning (RTLS), and no parking fees on highways (ETC part).
By mode of supply: non-, active, semi-active, corresponding to three different cost and life curves
The internal use of batteries and their role in the label directly determines how far it is read and write, life, price and use.
Unsourced Tab (Passive)
Passive tags have no battery. They draw all their energy from the reader's electromagnetic waves. The tag antenna picks up the signal, which is rectified to power the chip before the tag sends a response. These tags are long-lived, with a theoretical service life of more than 10 years, inexpensive at a few jiao to a few yuan, and can be made very thin. Most warehousing, retail, and logistics deployments use passive UHF tags. The trade-offs are a shorter read range than active tags and greater dependence on reader power and environmental conditions.
Active
An active label contains batteries that can launch a signal at their own initiative, with reading and writing distance of up to a few hundred metres or more, and can broadcast their position on time. It's common in container tracking, large asset management, people positioning. But batteries usually have a life span of 3-5 years, they need to be replaced; they are big and expensive (a few dozen to several hundred dollars) and not suitable for large-scale laying. A customer who manages a port container has been carrying active labels on the container, and it's re-posted with GPS modules, which is good but not cheap.
Semi-passive / BAP
Semi-active labels also have batteries, but the battery only provides power to the internal circuit of the chip, and communication is still triggered by a reader. This structure allows it to maintain the core function under small signals, suitable for temperature transfer, vibration transmission, etc., that requires sensor power. The logistics cold chain sometimes uses semi-source labels with temperature sensitivity, which are only enough for the transfer and storage of data, read or read.
By cover form: from nud inlay to industrial hard label, covering almost all physical environments
The sealing pattern is "can hold the scene," the frequency and power solution is "can read" and the sealing is "can survive after putting it on."
Inlay and Non-Dry Rubber Label
Inlay is the smallest unit with antennas and chips, usually made of non-dry glue labels on PET paper. This is the cheapest, thinst form that fits in boxes, plastic trays, files, books. The retailing of clothing, electrician logistics, library use most of it. It's afraid of water, metal, rough handling.
PVC card
Most PVC cards in the standard 85.6 × 54 mm size use HF. Access cards, membership cards, and campus cards generally fall into this category. A small number of UHF cards are also used for personnel identification. PVC cards print easily and look neat, but they cannot be bent too far.
Anti-Metallic Tags
These tags are designed for metal environments. A magnetic isolation layer or special antenna structure allows reliable operation on metal cabinets, racks, and pipes. A machining plant could not read standard UHF tags on metal pallets. On-metal tags restored the expected range immediately. They are more than twice as expensive as standard tags of the same size and are thicker.
Special seals: bandages, earmarks, scrubbing labels, wristbands, etc.
The laundry industry uses flexible labels of high-temperature and long-lasting chemical washing, which usually sew on weeds, to carry hundreds of industrial scrubs; animal headseting, sealing requirements for sunscreen, waterproofing, and lashing; hospital use of one-time wristbands, comfort and one-off identification are the main focus; logistics uses taped labels that can be attached directly to packages or equipment. Each is a specific scene, no common solution.
Selected experience: first set frequency band, then fix power, last pick-up
This is the sequence we've been using to do our projects, and it's a summary of how many pits we've stepped on.
Step 1: Choose the band based on range and application
Within 10 centimetres, non-metal environment, sensitive to cost - priority HF; several metres to ten meters, need to be read in bulk, with high assets mobile - UHF being the preferred; animal identification, metal penetration, special industrial scenes - LF or other special frequency band. Once the frequency is set, the type of reader and antenna follow.
Step Two: Choose a Power Source Based on Cost and Service Life
Batteries must be replaced and maintained later in time, at a total cost, not only by the unit price of the label.
Step three: Seal up according to the physical environment on the ground
This step is often ignored, but it determines whether the project can work in a stable manner over time. Metals are resistant to metals, high temperature environments are resistant to heat, outdoors are protected against sunscreening, and there is a need to clean up and clean up repeatedly. The seal is wrong, and two steps ahead are white.
We usually go through the scene with our clients first: metal share, liquids, temperature, humidity, if there is an impact, sun and rain, read speed requirements, and lay out the amount. This information is sorted and selected, and it's not very much a curved road.
The three dimensions of cross-section is the real result.
Tags used in actual projects generally combine choices across three dimensions. Pallet management might use passive UHF on-metal tags, library books may use passive HF adhesive tags, and container tracking may use rigid-encapsulated active UHF tags. A wrong choice on any dimension can compromise the whole system.
If you start to contact the RFID selection, it is recommended that you go in the broad direction from the "band" and then take a specific scene to the power supply mode and seal form. The same type of containment requirements may vary considerably from one industry to another, for example, with the same UHF passive labels, and the garment industry will use generic non-dry glue, and the metal parts industry will have to be resistant to metal packaging.
To be clear on all three, the RFID model is no longer a sense of brain-beating, but rather a logical engineering decision.