How to select rsfid tag bands: the applicable border between low-frequency, high-frequency and UHF
The RFID label is not "higher, better." Low-frequency, high-frequency (HF) and hyper-high frequency (UHF) have the appropriate border. The wrong-band selection often manifests itself as a failure to read, or as a result of environmental interference to offset the cost of input.
Sources of frequency band differences: two electromagnetic coupling methods
The exchange of energy and data by electromagnetic waves between RFID readers (also called readers, readers) and labels is not based on the same physical mechanisms for different frequency bands, which directly determines the read distance, ability to resist interference and the suitability of the scene.
Low-frequency and high frequency are a close-in coupling, the Electromagnetic Insistence Transfer between card readers' antennas and label antennas, which is similar to transformers, and is rapidly declining as soon as they are pulled away. So the reading distance in both bands is naturally short, and common reading distances do not normally exceed 1 metre.
The UHF is a distant coupling, the card reader is a radio-magnetic wave to space, and the label antenna receives energy and then reverses it back, which simply means sending back the signal back, so that it can read from a few metres to a dozen meters. But it's easier for the remote to be retrospected by metal, absorbed by liquids, and more "crazy."
The capacity boundaries of each of the three bands
The following is a video of the video:
| Frequency bands | Typical frequency | Common Read Distance | Mainstream agreements |
|---|---|---|---|
| Low frequency LF | 125–134 kHz | A few centimeters to a dozen centimeters. | ISO 11784/11785 |
| HF HF | 13.56 MHz | 1cm to 1 m | ISO 14443 / ISO 15693 |
| UHF UHF | 860–960 MHz | 1-10 m, partially capable of exceeding 15 m | EPC Class1 Gen2 / ISO 18000-63 |
Low frequencyThe advantage is that you have a good permeability, relatively friendly water, metal, liquid environment, simple label structure, cheap price. The cost is short reading distance, low transmission rate, small data capacity. Common uses include animal earmarks and livestock retroactivity, car fire protection, simple door-barrel recognition.
HFThe most familiar frequency, bus cards, second-generation IDs, door-barriers, book-proof labels are basically 13.56 MHz, and NFC on a mobile phone works in this band. It has medium reading distance, low tag costs, mature protocols, compatibility. When metal surfaces are used alone, they need a special high-frequency antimetallic label.
UHFIt is widely used in the field of logistics and retailing, with long reading distances, to support multiple labels (a antenna can identify hundreds of labels once at a time), suitable for storage points, retail outlets, logistics sorting, asset management, etc. It has two distinct short panels: one is water-resort, and high liquid-rich commodities are significantly less effective; and the other is metal, which reflects signals, and labels must be designed as a special anti-metallic structure to stabilize on metal.
Four key points of appreciation for the selection
The fact that the scene was broken down into specific questions was more reliable than hard back parameters.
How far do you need to read?Within 10 centimeters, within 1 metre, or more than 5 metres? This is the first question to answer. Once a reading distance has broken by 1 metre, low and high frequency is directly excluded.
What medium do you put on?Paper boxes, plastics and wood are largely clean; metals and liquids require special treatment. Low frequency is relatively tolerant of both media, and UHF is the most vulnerable to UHF.
How many do you want to read at a time?The selection of high frequency for single-document reading (door-barrel, ticketing) is appropriate; a whole tray sweep (the hundreds of labels are counted at the same time) can be essentially used only with UHF and HF cannot afford to swallow it.
What are the costs and label sizes?The UHF nudity labels are now generally down to a few cents, but metal-resistant tags, with sensor-specific models still cost much more than HF. If the labels need to be done very little (e.g. plastered or embedded into the product), low frequency and high frequency can be easily achieved.
A few pits in the real project that can easily be stepped on.
We've seen several recurring errors in our RFID program.
The one-time error: UHF read it well.Some customers come up and say, "I'm going to read 10 meters," but it is more realistic for them to have a metal swirl or a liquid barrel that the UHF either cannot read at all or below half of the recognition rate.
Mistake II: Ignore differences between protocols and regional bands.The UHF frequency bands vary from country to country: China is 840-845 MHz and 920-925 MHz, Europe 865-868 MHz, and the United States 902-928 MHz. If equipment does not match local frequencies, reading distance can be significantly reduced or even impossible to work. Shanghai-Shanghai-Jing will include this item in the selection list when it comes to a project for export.
Mistake III: An antenna layout and environmental assessment not done.The UHF is particularly sensitive to the field environment, and metal shelves, ceiling reflections, and movement of people affect performance. Formally, it is done by conducting on-site electromagnetic environmental assessments before determining antenna numbers, locations and power levels, rather than loading them up for remediation.
Summary
Three bands are not absolutely good or bad, only if the scene matches. Just remember: low frequency is suitable for a high penetration requirement and short reading distance; HF is a common option that balances cost and compatibility; UHF is appropriate for long range, multiple-label batch reading, but must address interference with metals and liquids. Compare the above to determine whether the RFID project will fail much less.