Is the rfid tags available: active tags, uwb versus passive program capabilities
The RFID labels can be located, but the "location accuracy" varies considerably. Passive tags only identify "where" areas, active tags can reach room levels (3-5 metres), UWB labels can reach centimetres. The choice depends on how accurate, covering and budget you need.
Point 1: Three-phased location needs. First, figure out which one you want.
The term "location" is used in the project in a broad sense, and it actually corresponds to three different sets of needs:
- Existence test: Knows this thing is not in this warehouse or this store.
- Regional positioning: Know if it's in Area A or B, 3-10 meters.
- Precision coordinates.: Know where it's in the room, 10-30 centimeters.
The different RFID programs are different. First, you set the one you want, then look at the next technology and think better.
Point 2: Passive RFID -- "Assisting" and not "coordinate."
Passive labels do not have batteries, and radio-frequency energy from a reader is powered and sent back. Readers read signals indicating that the label is within the range of the radio frequency; they are not read, either by the label or by metal, liquid.
Typical reading distance:
- HF (13.56 MHz): 1-10 cm, mostly for door-barreling, payment, IC card
- UHF(860-960MHz): as far as 10-15 m, but the physical environment is more affected by metals and liquids
"Leave" is done using passive solutions, which are essentially defined by the deployment of multiple readers. For example, in warehouses, there is a reading machine for A and B shelves and C shelves, and where the labels are read, it goes. This way only goes to shelf or room levels, 3-10 meters with no specific coordinates.
Suitable scene: warehouse inventory, library book search, retail burglary trigger, door-to-door access log.
Point 3: Active RFID - Practical options for room-level positioning
Active tags have a built-in battery and transmit their own signal. A common frequency is 2.4 GHz, and 433 MHz options are also available. With one transmission every few seconds, the battery typically lasts 3-5 years.
Two mainstream approaches:
- RSSI Positioning: Rewind distance of signal strength from label to multiple readers, 3-5 metres accuracy. Simple deployment but vulnerable to environmental disturbance.
- TDOA positioning: The time difference between the different readers is calculated by signal, with precision of up to 1-2 m. The exact clock sync between the readers is required and deployment costs are slightly higher.
In a factory project, the goal is to track 50 transients, and it requires "know which workshop the tool is" that 3 m accuracy is enough for the operation. If you switch to UWB, each label cost up to an order of magnitude, it's not a good idea for this scenario. The source RFID is a more balanced option in this demand.
Suitable scenario: plant tool tracking, location of hospital equipment, park vehicle management, call-up for personnel attendance.
Point 4: UWB - cm-scale precision, but at the expense of accuracy
UWB (ultra-wideband) is a different technology from conventional RFID, but it is included here because the two are often compared for positioning. UWB measures distance with nanosecond pulses. It is highly resistant to multipath interference and can achieve 10–30 cm accuracy.
Key parameters (common industry range):
| Positioning Accuracy | 10-30 cm |
| Single Label Cost | Usually 5-10 times the source RFID. |
| Single-base cost | Much higher than the normal RFID reader |
| Battery re-energizing. | 6-12 months, with frequent replacements |
| Typical overwhelm radius | 30-100 m (VOC) |
UWB fits into a highly accurate scenario: factory AGV track, miner precise location, high-value asset tracking, prison staff control. Note that UWB deployment is more complex than RFID - the base station position needs to be accurately measured and marked, and there are requirements for site environment and covertness.
Point 5: Select four dimensions.
Simplify the selection decision into four questions, and then basically lock down the programme in order of question.
1. How much precision is required?
- Plasma level (3-10 m): Multi-reader Passive Program
- Room level (3-5 m): Active RFID+ RSSI
- Centimetres (10-30 cm): UWB
2. How much coverage?
- Small doorshops/small warehouse: passive solution is enough
- Plant/horizon (thousands of square metres): active RFID
- Large plant area/complex space: UWB multi-station network
3. Are labels continued?
- Passive: no batteries required
- Source RFID: 3-5 years
- UWB: 6-12 months
4. What is the budget for individual labels?
- Passive label: A few cents to a few bucks.
- Source RFID: dozens of dollars
- UWB: Hundreds to thousands.
After the four questions had been answered, the programme was largely locked.
Point 6: Increased use of mixed programmes in actual projects
Few projects use only one RFID program.
- Warehousing scenes: UHF passive label to take a whole inventory + active tag to track high-value goods in real time
- Plant scene: UWB for key positions or AGV positioning + regular RFID for tool access library registration
- Hospital scene: active RFID for valuable device tracking + passive label for waste material management
Shanghai-based technology has been using these four dimensions to distil demand in a number of smart storage and plant positioning projects, before deciding which areas are active and which ones are passive, avoiding one-size-fits-all cost waste.
And let's sum up: Position accuracy and cost are two ends of the plate. Passive solutions are cheap but only tell you "in or out," source RFID is a balance point in value, UWB is high in value, but it costs more. First, you need to be sure that your precision slots are better, then push them back, than just parameters.

Ms. Lei
Mr. Pang