Is the rfid tags available: active tags, uwb versus passive program capabilities
RFID Knowledge

Is the rfid tags available: active tags, uwb versus passive program capabilities

PublishedShanghai Zejie Smart Technology Co., Ltd.

The RFID labels can be located, but the "location accuracy" varies considerably. Passive tags only identify "where" areas, active tags can reach room levels (3-5 metres), UWB labels can reach centimetres. The choice depends on how accurate, covering and budget you need.

Point 1: Three-phased location needs. First, figure out which one you want.

The term "location" is used in the project in a broad sense, and it actually corresponds to three different sets of needs:

The different RFID programs are different. First, you set the one you want, then look at the next technology and think better.

Point 2: Passive RFID -- "Assisting" and not "coordinate."

Passive labels do not have batteries, and radio-frequency energy from a reader is powered and sent back. Readers read signals indicating that the label is within the range of the radio frequency; they are not read, either by the label or by metal, liquid.

Typical reading distance:

"Leave" is done using passive solutions, which are essentially defined by the deployment of multiple readers. For example, in warehouses, there is a reading machine for A and B shelves and C shelves, and where the labels are read, it goes. This way only goes to shelf or room levels, 3-10 meters with no specific coordinates.

Suitable scene: warehouse inventory, library book search, retail burglary trigger, door-to-door access log.

Point 3: Active RFID - Practical options for room-level positioning

Active tags have a built-in battery and transmit their own signal. A common frequency is 2.4 GHz, and 433 MHz options are also available. With one transmission every few seconds, the battery typically lasts 3-5 years.

Two mainstream approaches:

In a factory project, the goal is to track 50 transients, and it requires "know which workshop the tool is" that 3 m accuracy is enough for the operation. If you switch to UWB, each label cost up to an order of magnitude, it's not a good idea for this scenario. The source RFID is a more balanced option in this demand.

Suitable scenario: plant tool tracking, location of hospital equipment, park vehicle management, call-up for personnel attendance.

Point 4: UWB - cm-scale precision, but at the expense of accuracy

UWB (ultra-wideband) is a different technology from conventional RFID, but it is included here because the two are often compared for positioning. UWB measures distance with nanosecond pulses. It is highly resistant to multipath interference and can achieve 10–30 cm accuracy.

Key parameters (common industry range):

Positioning Accuracy 10-30 cm
Single Label Cost Usually 5-10 times the source RFID.
Single-base cost Much higher than the normal RFID reader
Battery re-energizing. 6-12 months, with frequent replacements
Typical overwhelm radius 30-100 m (VOC)

UWB fits into a highly accurate scenario: factory AGV track, miner precise location, high-value asset tracking, prison staff control. Note that UWB deployment is more complex than RFID - the base station position needs to be accurately measured and marked, and there are requirements for site environment and covertness.

Point 5: Select four dimensions.

Simplify the selection decision into four questions, and then basically lock down the programme in order of question.

1. How much precision is required?

2. How much coverage?

3. Are labels continued?

4. What is the budget for individual labels?

After the four questions had been answered, the programme was largely locked.

Point 6: Increased use of mixed programmes in actual projects

Few projects use only one RFID program.

Shanghai-based technology has been using these four dimensions to distil demand in a number of smart storage and plant positioning projects, before deciding which areas are active and which ones are passive, avoiding one-size-fits-all cost waste.

And let's sum up: Position accuracy and cost are two ends of the plate. Passive solutions are cheap but only tell you "in or out," source RFID is a balance point in value, UWB is high in value, but it costs more. First, you need to be sure that your precision slots are better, then push them back, than just parameters.