How much temperature can rfid labels typically withstand: material versus condition
RFID Knowledge

How much temperature can rfid labels typically withstand: material versus condition

PublishedShanghai Zejie Smart Technology Co., Ltd.

Last winter, a client who was in storage for the cold chain came up and said that it started reading from the labels on the outer case to -15°C. We took down a few defunct tags, the chip was not broken, the welding was not loose, the problem was the face of the gels, the labels were dropped out of the box. Then a PET face was branded with low-temperature glue, which was also three months running without any further problems. This made us realize that the RFID labels could carry temperature, not a fixed number, but a chip, antenna, foundation, embottle and sealing process.

What part of the label is the temperature affecting?

Many people think that the RFID labels are intolerant to high temperature, looking at the chip is not quite right. A complete label usually consists of four layers: a chip (naked chip or encapsulation), a soft panel (PET or PI film) carrying the chip, a face (shell or sticker), and a laminated layer or coating. Each layer has its own limits.

The working temperature of the chip itself (in common cases such as Alien, Higgs, Impinj Monza) is usually between -40 °C and +85 °C, which is a physical limit for the silicon semiconductor itself. After over 85 °C, the ability to read and write the chip will decline significantly, but not necessarily immediately; below -40 °C may cause slow response or complete failure to return.

The true limit of the label is often an outside wrap. The chip may hold 100 °C, but the face has been softened and deformed; or the chip can work, but the film loses its stickyness at low temperatures, and the label is unstamped. So the selection should not look at the chip specification only, so the whole label should be seen as a component.

Temperature range for common materials

The following table is a common material comparison that we have compiled, based on data from the public datasheet of chip manufacturers and materials suppliers, to the extent that actual products may also be affected by glue, sealing processes for information purposes only:

Material Type Typical working temperature Applications
Paper label (copper / hot-sensitive paper) -20°C to +70°C General commodity labels, paper instruments, logistics sheets, short-term use
PET / PEG face -40°C to +85°C Cold chain logistics, outdoor asset identification, torn protection applications
PP (polypropane) pasta -40°C to +85°C Soft chemical corrosion resistance needs, such as in the washing industry, medical reagents
ABS hard-shell label -40°C to +80°C Tool management, IT assets, outdoor equipment
PPS (polyphthalethers) hard case -40°C to +150°C Automobile engine cabin, industrial bakery, paint shop
Ceramic Seal Label -40°C to +250°C (partially available up to +400°C) Metal smelting, kiln management, high temperature modelling
Silicon / Eeptoxy Encapsulated Softness Label -40°C to +200°C. Alien arctic, high-temperature liquid impregnated, auto-assembly

The following are some of the most important issues that require special attention:Working and storage are different things.. Many labels have a much wider storage temperature than the working temperature, such as the work temperature - 40°C to +85°C, which may allow -50°C to +100°C when stored because the pressure is more relaxed for the temperature when power is not available.

What do you say we do with the typical job?

Cold chain and cryogenic storage

The freezer is usually -18°C to -25°C, and deep-frozen speed will reach -40°C. In this environment, ordinary paper labels are crystallized, paper becomes thin, PET surfaces are propylated with low temperature. We have a plan for an imported food client, the storage area is used year by year - 22°C, and they start with normal hot paper labels, and then they are retried once a month. Then they replace PET with 3M low temperature special glue, which is running without any error for a year.

Industrial laundry and textile management

The washing labels are not just about temperature, but also water, chemical aids and mechanical power. The work cycle is usually 90 °C above hot water wash, 150 °C when drying, ironing up to an occasional 180 °C. This scenario can basically be based on a PPS flexible label or a silica seal, which is often unconvinced by repeated high-temperature bakery. When we did the hotel weed RFID project, the first version of the label was only a month old, and the second edition was replaced with a PPS-encumbered structure, which is now in service for three years.

Medical sterilization and laboratory

Medical equipment is commonly used for antibacterial use at high temperature and pressure (121 °C to 134 °C) or epoxyethane, gamma-ray irradiation. The RFID labels dedicated to the retroactivity of devices need to be tested through ISO 17665, so that a general label will fail as soon as it is overpressurized. These labels are typically sealed with ceramic or PPS, and work temperatures can be -40 °C to +150 °C, designed to keep special memory data, ensuring that post-temperature antibacterial data are not lost.

Motor and metal high temperature

In the engine compartment, near the brake system, the temperature peak of the exhaust pipe can be 150°C to 200°C. This position must be marked with ceramic labels or PPS hard-shell anti-metallic tags, which are not readable on the metal surface by vortex effects, and which, together with high temperature softening, will last less than a month. We have done a retroactivity project for parts from the whole plant, which eventually is a PPS-encapaciated epoxy-encumbered, capable of working at 150°C for more than 200 hours.

Long-term outdoor exposure

Open-air devices or asset labels are subject to a temperature difference by day and night, ultraviolet light and rain. The northern winter is likely -30°C, and the surface of the metal in summer 70°C is normal. This situation is where UV ink printing is used on a pP or PET face, with glue choosing to be wide-resistant (e.g. -40°C to +150°C modified acetate) that cannot be used as a general thermogel.

A few pits that can easily be used in the selection and testing.

Just watch the chip katasheet.The chip sign - 40°C to +85°C does not mean that the entire label is also usable. Some manufacturers only measure the chip, and the actual working temperature range of the entire label is not verified.

Use the storage temperature as working temperature.Storage temperatures are wider than working temperature, but the temperature limits shrink once labels are placed on products to work.

Ignore the limits of the duct.The glue is often the first to fail in a low temperature scenario, and it is sensitive to both face and chips.

No actual work-testing.There is a gap between the constant and wetness test in the lab and the real scene. It is recommended that a round of high-temperature cycle tests be performed with samples before the official bulk purchase, running at least 5 cycles per 24 hours each -25 °C/70 °C, to see label reading distance decay and film change.

If you are evaluating an RFID project, first establish the actual temperature range, including peaks and lows, duration, and frequency. Use the material table above to narrow the options, then compare two or three candidate tags on site. Shanghai Zejie Technology has extensive experience selecting industrial RFID tags. Temperature, material, read range, and mounting method generally need to be assessed together. Choosing based on one factor alone can lead to the wrong tag.

Finally, to conclude: The working temperature of the normal RFID label is roughly between -25°C and +70°C. Main plastics can be -40°C to +85°C, PPS and ceramics can cover -40°C to +150°C or higher industrial scenes. Selecting the temperature curve on the ground, attach the base material, read distance, life requires these four variables to be considered together, and a round of empirical verification will largely avoid most of the pits associated with the temperature.