Industrial rfid reader selection guide, points for channel number and frequency band configuration
Industrial RFID readers select the number of channels and frequency bands that are easily ignored, but have a significant impact on subsequent use. The frequency ranges determine penetration, the type of interference-resistant and fit labels, and the number of channels (i.e. the number of antenna ports that the reader can drive simultaneously) directly determines the ability to cover and the rate of failure in the identified area. The two are not isolated options, they must combine the label type, install space, and move beats are judged together, otherwise the working time for filling the tags is repeatedly consumed.
Step one: untangle the scene, and don't rush over the parameter table.
Before the selection starts, three questions are answered: what material the labels are on, where the identified target moves in, and how the rhythm is required in a few seconds. If these questions are not clarified, any higher parameters will be hit on the face.
Labels and Material Features
The UHF label on the box, the plastics, the conventional UHF band can be read at a distance of several metres. If it is metal loads, liquid drums, special labels on medical devices, the normal tags will fall within 1 metre of identification, and must be replaced by an anti-metal label or flexible anti-liquid label, which directly relates to the trade-off between frequency and power.
Installation of space and environmental interference
The sources of interference at the site of the production line include a frequency transformer, an electric machine, a metal support frame, and welding. The UHF band is sensitive to these disturbances, the layout antenna is more than 1 metre away from the jamming source proposal or is fitted with suction material on the metal rack. The failure in many retrofitting projects is often due not to the reader itself but to the influence of the surrounding variable or high power power generator, which improves significantly the reading rate after adjusting the antenna position and loading the suction material.
Frequency selection: the UHF and HF are divided, not replaced
The two frequency bands most commonly used by the industry RFID are UHF (frequency band range 860-960 MHz) and HF (13.56 MHz), each with a good set of scenes and no general optimal solution.
UHFRead distance (typically 3-8 meters), read group speed (more than 200 labels at a time), suitable for warehousing access, logistics sorting, and rhythmy production lines. The weakness is that it is easy to be reduced by metal fluids, and the distance identified when labels are placed on the metal surface is significantly shorter.
HFGood penetrance, strong resistance to metal fluid interference but short reading distance (typically 0-30 cm), slow group reading, usually used for the identification of work-packages, knife-set management and tracking of these scenes in small material boxes.
Some projects combine two bands: UHF for bulk throughput and HF for interference-resistant reads at critical stations. Plan the interfaces and protocols when selecting equipment.
Number of corridors: Push backwards from identified areas and rhythm
Readers' "passages" are the number of antenna ports that can drive simultaneously, with common specifications for single channels, 4 channels, 8 channels, and 16 channels. The number of channels is not as good as it is, and it is directly linked to costs, connection complexity.
Experience in determining the number of corridors:
- Measures the width of the area identified. The general single-polar antenna covers 0.8-1.2 metres in diameter, folds over each other ' s adjacent antenna beams and links approximately equal to the width of the area of identification divided by a one-ray radius, then adds one or two additional parts upwards to the whole.
- Determine the cycle time. If one item must be identified within three seconds and the conveyor runs at 1 m/s, allow at least 3 m for the read zone, typically with three or four antennas.
- Consider the angle of the label. The label may enter from the front, side, bottom, and the antenna will be staggered and the number of channels will be set aside for this increase.
For example, a line with a linear width of 0.6 m and a nodal 2 seconds requires the identification of labels for multiple angles at the bottom of the tray. The common practice is that 2-channel readers are accompanied by 4 antennas, which are staggered in the direction of the other, and this combination usually has low drop rates.
Power, antenna and field layout.
The upper limit of the URRP in the regional UHF frequency range of China is 2W ERP (920-925 MHz) and cannot be selected with only the maximum value of the output power of a reader, depending on whether it can actually be moved to the workspace, or if it can remain stable under different antenna configurations.
Antenna gain, beam angle, polarization direction match the scene:
- Remote, single-direction scenario: Select the high-benefit (8-12dBi) orientation antenna.
- Arcades are dense and unorthodox: Select a low gain (5-7dBi) round polarized antenna.
- Metal base environment: An antenna is at least 30 cm from the metal surface, with plastic support up when necessary.
Once the number of channels is determined, whether each channel drives several antennas, the subdebates into two paths or directly one-way connections, it is to be finalized at the selection and to avoid a later detection of duct space.
Interface, protocol and top-up match
Readers are not isolated devices, they connect to PLC, gateways, and the above-place MES interfaces, common industrial interfaces include Profinet, EtherCAT, Modbus TCP, Ethernet/IP, also with RS485 or TCP/IP custom protocols.
The method of triggering the scene is also to be clear:
- Sensor Trigger: Judge the object when it is in place with a photovoltaic or close switch, and read it after it has been in place, and the rhythm is steady, leaky and low, suitable for a controlled line of production.
- Roundup ModeReaders read and write continuously, PLC takes up-to-date data as required and is suitable for the transfer belt, multi-position shared scene.
The interface type is finalized at the PLC end in the early stages of the selection. Shanghai-based Cheeky Way Technologies has returned several times to work on the project, all because the PLC-end only supports Profinet, while the reader only supports EtherCAT, and then only replaces equipment or adds a gateway. This pit can be avoided one day in advance.
Several recurrent selection errors.
Combining the reader selection with the antenna selection.Reader body, frequency segment module, antenna, feeder, label is four separate units, and any mismatch will drag down the whole line. The common phenomenon is to focus on the distance of reading that is promoted by the writer, without looking at the environment in which the actual material is posted on the site, resulting in a decline of more than half the physical distance.
The number of corridors left was insufficient.Production processes and tag specifications often change later. If every channel is occupied from the start, there is no room to expand. Allow 20%-30% more channels than calculated. Running out on a four-channel reader is a bigger headache than having spare ports on an eight-channel unit.
The protection level ignores the situation on the ground.The standard reader protection level is IP54, with a rinse-and-fog environment on the production line to choose an IP65 or even IP67 level, otherwise the equipment will not last for several years and the cost of shutdown of the entire line is much higher than the cost of the equipment.
An enforceable list of options
In summary, the industrial RFID reader type is more secure in this order:
- (b) Recouping label types, installing materials and identifying distance requirements;
- Identification of sources of environmental interference, protection level requirements;
- (b) Number of inverted paths by the nodal and identified area (plus 20-30%);
- (a) The fixed frequency band, the reading and writing power range, antenna type and polarization direction;
- (a) Clarify interfaces, protocols, triggers and pre-interfacing with PLC or the aircraft on board;
- A two-week run in small quantities, with a statistical gap and nodal compliance, will determine whether or not to procure the bulk.
The industrial RFID selection does not have a one-size-fits-all formula, and each line has its own details. The solution to land is often to tear the scene down sufficiently finely, to compare parameters with field conditions, rather than just to look at the beautiful numbers in the parameter table.