What about the asset RFID management software?
A machining factory kept more than 3,000 sets of fixtures and jigs in its warehouse. Two people spent three days on the monthly count, and dozens of sets still failed to match the register. The supervisor scanned with a handheld close to the tags. Some read at a dozen or so centimeters; others only worked up close at a different angle. The review found the reader frequency and antenna orientation were correct. The metal racks were blocking the signal, and the tags were not designed well enough for use around metal. When choosing management software for RFID, which identifies items using radio waves, the first question is not about the software. It is whether the reader and tag setup can cope with the site.
Let's get this whole scene down and talk about the configuration.
The most easily stomped pits are the parameters and list of items. RFID is not a general product, unlike metal, liquid, dense piles, where the mix of readers and labels is completely different.
The inventory is divided into three broad categories:
- The inventory is used by the person with the equipment to move between the shelves and to fit a thin label, an unsettled location of assets such as laptops in the office area and measuring devices.
- The property is automatically registered at the warehouse entrance and in the workshop aisle.
- Read in smart shelves/cools. Reader and writer antennas are embedded inside the shelf partition or cabinet, and fit a scene of "take-in-the-sensor" needs for precious small pieces, tool rooms, reagent cabinets.
The number of antennas, power ranges, label sizes and sealing materials vary very much. When Shanghai-based Cheeky Way Technologies is doing their work for clients, the first step must be to go to the scene and see what the asset is, how it is set up, what the people's motion lines are, and then determine the hardware mix.
Reader: Three things to figure out: frequency, antenna, power.
The most common UHF UHF RFID in the country (working frequency 860-960 MHz) is a distance, which can sweep dozens of labels at a time, and is the mainstream choice for asset management. When you select a reader, these parameters should be kept close:
Matches the reading distance and actual scene
The factory labels say reading distance is often measured in an empty environment, for example, 8 metres, 10 metres. At the site, affected by metal reflection, labels, stack density, actual reading distance usually needs to be folded or even lower. The door-ban channel is used 3-5 metres enough, and a warehouse needs more than 6 metres to make remote inventory.
Number of antennas and how to polarize
The diametric antenna is not sensitive to labels, and suitable for the irregular setting of assets; it has a longer reading range but requires a relatively fixed direction. The portal usually has 2-4 antennas, and the reading within the shelf normally takes place with an antenna. The more expensive the antenna, the less the better the asset, the more the signal is, the less the signal is read.
Power and geographical compliance
There are clear domestic launch power limits for the UHF band, which generally do not exceed 33 dBm EIRP (the full irradiation power equivalent, an indicator to measure wireless signal strength). The excess limit is not only problematic in terms of compliance, but also interferes with other devices around it. So when you select a reader, the removable range of power is a hard indicator, not just maximum power.
Label: Anti-metal, Seal, Protocol Three Levels
The factory in front last changed the label. It was a normal paper label, which could hardly be read on metal. When it was sealed with ABS (engineering plastic) with an anti-metal layer, the same shelf, the same handheld, was pulled from less than 60% to over 98%.
The following three features are highlighted in the tab selection:
- The metal surface must be marked with a metal-resistant label, the liquid environment with a soft liquid-resistant label and ordinary plastics, wood surfaces with a standard label.
- Size and margin of reading. The larger the label, the longer the antenna, the distance. But small pieces of asset can only be labelled with small labels, short reading distances are physical limitations and need to be filled by sensitivity on the side of the reader.
- The air interface protocol for the reader and label (ISO 18000-6C is currently mainstream) must match, otherwise there will be a problem of "reading but writing down" or slow reading. Better get a connection between the writer and the labeler before you go to the store.
Management software: Not just an interface, but a connection with hardware
The management software is often used as a core, but it's more like a dispatcher. The real decision about how the RFID system works is whether the software can tie up readers, labels, data operations.
- If the software locks down only from home hardware, it is difficult to change the manufacturer later.
- Can you configure antenna groups, read power, and trigger conditions? For example, if the four antennas on one reader correspond to four shelf levels, the software must be able to read by zone instead of turning them all on at once.
- Data is heavy and abnormal. A single inventory may read the same asset dozens of times, and software is heavy; missing assets are marked to facilitate cleaning, which is more practical than a fancy board.
- The data are ultimately placed in the financial and procurement systems, without which the manual guide sheet is the only means of matching the existing ERP, MES (manufacturing implementation system).
When doing the project, Shanghai-based Quest usually allows software to be associated with a reader for more than a week, running every typical scene on the site and confirming that read-out and error rates are acceptable in range and then go online.
Configure List: Check yourself before you go online
I'll take the top of the list and go over it before I go online, save most of the late work:
- The inventory is confirmed: handheld, passage or inside the shelf.
- Is the reading/writing power, number of antennas, and polarization matching the scene? Are the power within compliance?
- Does the label cover match the asset material? Am I free of metal, anti-liquid or conventional?
- Has the reader and label been connected? Are there any data on the reading rate of typical scenes?
- Does the management software support antenna grouping, power reconciliation and data weight?
- Are interfaces with ERP and MES working? Is the data going well?
RFID asset management is a combination of fists, and single points are not the best of systems. Running this list once before selection and online, it avoids almost 80% of common pits.