What does the electrical spare parts management system say? Class and storage requirements
The core of the electrical spare parts management system is to make "classify, store, desk, account" clear. A landing system usually includes scope of application, a catalogue of spare parts, storage conditions, access processes, inventory cycles and segregation of duties. Below is an article by article.
Point 1: To put together the framework for the classification of spare parts
Classification is the basis of the system. It is suggested to divide it by three dimensions, "Class of equipment + materiality + interchangeability", rather than simply listing it by electrical components.
- By equipment category(c) Low pressure electrical categories (exposers, relays, circuit breakers), electric machines and tugs, instrumentation and sensors, cable and connection types, power sources and batteries.
- By importanceCategory A (core components of critical equipment, with significant impact on the shutdown), B (commonly used items for general equipment), C (support or consumables). Category A must be available at a scale of 1:1 or higher.
- By Swap: Same model, generic replacement model, custom package. Generic alternatives can compress inventory and customizations are individually numbered and managed.
The catalogue recommends that it be included in the form of a table in the annex to the system, which will facilitate subsequent additions made by way of the same rules.
Element 2: Identification of storage conditions for the various product categories
The following table can be copied directly into the system:
| Type | Temperature | Relative humidity | Other requirements |
|---|---|---|---|
| Elementware (PLC module, relay board) | 0~40℃ | 30%~70% | Static, tidal, original packaging storage |
| Electrical and large equipment | -10~45℃ | ≤75% | The mat is 10 cm above ground, and the axle end is stainproof. |
| Cables and wires | -15~40℃ | ≤80% | Avoid the sun and no pressure. |
| Battery types | 5~30℃ | ≤60% | Regular power replenishment and monthly voltage check |
| Instrument and Sensor | 0~35℃ | 45%~75% | Take it easy, save the accompanying certificate with the file |
The reference is based on the GB/T 15464 General Technical Conditions for Instrument Packing and the storage environment provisions in the manufacturer’s product manuals.
Point 3: Storage hardware and marking specifications
The location and marking of the warehouse is an easily neglected part of the system, but it has a significant impact on actual management.
Location and layout of the warehouse
- Independently designed to avoid areas of production where vibration, corrosive gases and strong magnetic fields are occurring.
- The 30 per cent space for expansion is set aside on a total basis to avoid moving the new items.
- The shelf loads match the weight of spare parts, electric machines, heavy-duty contacts are placed on the ground floor and light small elements are placed in the upper layer.
Identification and billboard
- Each location is marked with a "Landing Four" sign: the storage area -- shelf -- layer -- bit.
- The spare parts label contains material code, name, specifications, date of entry into the warehouse and date of re-examination.
- The billboards are recommended to be electronically or in EAM systems, at least for recording: code, name, model, quantity, unit, location of storage, supplier, batch, date of entry, date of release, current status (in the library/used/under repair/reuse).
Point 4: Access to the library and access process
The more specific the process is, the less obfuscated it is to be implemented.
- Applications for applicationsUse the department to fill in the receipt, indicating the name of the equipment, the location of the failure, the number of spare parts required and the quantity.
- PermissionsCategory A spare parts are approved by the equipment supervisor and categories B and C by the class commander or engineer.
- Out-of-house reconciliation:: Treasury clerk voucher, to check the code, specifications, batches and confirm that it is not damaged.
- Registration desk accountsThe desk accounts are updated as soon as the warehouse is released and spare parts A will be synchronized with replacement time and operator in the equipment files.
- Back to the rest of the bank.: Unused spare parts will be returned within 7 working days and the income pool will be re-examined upon return.
Point 5: Inventory and life-management
The spare parts are not in use and will also fail, a blind zone for many systems.
- Inventory cycleA-tests are conducted 20 per cent a month, quarterly and overall; B-quarters; C-biannually.
- Recheck Project: Electronics for electrical or visual tests, electrics for insulation resistance (>=1M is valid), batteries for voltage and capacity testing, rubber seals for ageing.
- DismissalSpare parts beyond their warranty period or unsatisfactory re-examination are moved to the restock or scrap area and may not remain in storage at category A warehouse.
- Life-long early warning: For components with a specified useful life (e.g., capacitor, battery, seal) an automatic reminder is set in the account 60 days before expiry.
We found that, in helping some manufacturing firms to comb the spare parts system, the four steps would reduce the stock of undefeated material from 20 per cent to less than 5 per cent and the time for failure of critical equipment was significantly reduced.
Element 6: Structure and landing of institutional documents
A complete system document, with the following skeletons recommended:
- Chapter I General provisionsPurpose, scope of application, reference criteria (e.g. GB/T 15464, internal equipment management approach).
- Chapter II Division of responsibilities• Specific duties of the Department of Equipment, the Treasury Manager, the User Department and the Vendor Management Service.
- Chapter III Rules for the classification and coding of spare parts: with examples of catalogues and codes.
- Chapter IV Stock standards and procurementMaximum and minimum stock of spare parts for category A/B/C, method of calculation of place of purchase.
- Chapter V Storage and maintenance: This is the content of point 2, 3 here.
- Chapter VI Access to the library and access: Process for element 4.
- Chapter VII. Inventory, review and scrapping: the content of point 5.
- Chapter VIII. Examination and by-laws: the way in which indicators such as the inventory error rate, spare parts availability rate are evaluated.
The file length control is more appropriate at 3,000-5,000 words, too short to execute the sample, too long. The corresponding log template for each chapter is attached at the end, such as the spare parts entry and inspection sheet, the checklist, and the recheck log form, which facilitates direct printing.
The last step is to run the system: piloting 1-2 account periods in 1-2 workshops, collecting feedback from the storekeeper and maintenance staff before re-issuing. Shanghai-based Cheeky Waytech usually spends 3-4 weeks consulting clients on the spare parts management system, completing a complete delivery of the catalogue to the billboard template, ensuring that the system can be implemented on the day of its release, rather than remaining on paper.

Ms. Lei
Mr. Pang