How do you choose the RFID asset count tag? Type appropriate to the work situation
Answer: The label is not price, but work.
When taking stock of assets, many people are stuck in the first step: UHF, HF, anti-metallic, soft, hard and so many different types, not knowing which. The core test for the actual selection is three -Read enough distance, can the surface material fit, and how much of the assets are covered by the budget. Clear these three, the label type is locked. Here we go in contrast.
By frequency type: LF/HF / UHF how
RFID splits low frequency (LF, approximately 125-134 kHz), high frequency (HF, 13.56 MHz) and hyperfrequency (UHF, 860-960 MHz). Three types of label vary in reading distance, resistance to interference, and costs, and directly determines whether it is usable or not.
| Frequency Type | Typical Reading Distance | Anti-metallic/liquid | Single Label Cost Range |
|---|---|---|---|
| LF Low Frequency | 0.05 – 0.3 m | Small interference with metal fluids | About $1–5 |
| HF HF High frequency | 0.1-1 m | Medium resistance to interference | About 0.5-3 yuan |
| UHF UHF | 3-10 m (no source) | General labels have been significantly reduced in metal/liquid performance | About $ 0.3-2 |
Criteria of judgement: If a warehouse shelf is full tray count, the bulk count is fast, and the UHF is given priority; if a single asset is located precisely, a close-to-one first reading will be required, and the HF will be more appropriate; if it is a metal-intensive machine or power plant equipment, or if it needs to penetrate a liquid environment, the LF will be more stable.
The trade-off in the actual project
A customer who made a carbide storage first picked the normal UHF label cheaply, and then dropped the reading rate below 60% after putting it on the metal tv, then replaced it with an UHF anti-metallic tag. In similar projects, Shanghai usually takes the surface material of the asset at the site, reads distance requirements, asks how often the batch count is checked, then flips the frequency type, and avoids stacking parameters at the top.
Compared by cover form: Soft / Anti-metal / Hard Label
When the frequency is set, the next step is to look at the form of the seal. The different packagings determine whether the label can be placed on the side, can hold the metal environment, and can withstand high temperature oil pollution.
- Soft Tag (inlay + PET face)0.5-1 mm thick, bent, suitable for plastic casings, wood furniture, and archive boxes. Low cost but not high temperature, inappropriate for outdoor or industrial oil pollution.
- Anti-Metallic Tags: Insorption materials or stair layers, which are designed to address the surface signal decay of metals. Common thickness 2-4 mm, with unit prices usually 3-5 times the normal UHF label, but reading distance is stable at 3-8 m.
- Hard Label (ABS / PPS shell): The temperature-resisting range is usually -40°C to 150°C, with impact-resistant and water-proof dust-resistant levels up to IP68, suitable for outdoor electrical equipment, machine floors, chemical containers.
Criteria of judgement: Surface is plastic, paper, curved softness; surface is metal or a near-metallic must be selected to resist metals; the environment has high temperatures, oil pollution, water washing, outdoor exposures select hard matter + corresponding level of protection. Do not try to push flexible labels on steel plates, which are almost impossible to read.
Cost comparison: not just unit prices, but full cycle
The label cost cannot be counted as a single price, but must add up three pieces:
- Label unit price: The larger the lot, the lower the unit price, the more than 10,000 UHF general labels can be within 0.5 yuan, the anti-metal tags are usually 2-6 dollars, and the hard-quality high temperature label 5-15 dollars.
- Accompanying reading and writing devices: A handheld UHF reader costs CNY 2,000–8,000, and a fixed portal reader CNY 3,000–15,000. HF equipment is cheaper, making the overall entry cost lower.
- Transport and replacementThe second procurements that result from mislabelling, re-labelling the manual, which is often a big covert head. We've seen a project, because it started with the heat intolerant labels, and the workshop changed in six months, but it cost almost twice as much budget than it did with hard labels.
Criteria of judgementHigh value, long-term use, bad environment, choice of a little more expensive but durable; large number of assets, low single value, short life cycle, and enough to make it cheaper.
Applicable scene comparison: From office to workshop
The following is a typical combination of the following:
- Office / Archives: HF+ Soft labels, which are low-cost for each item and can be satisfied by a closed reading or writing.
- Warehousing shelves / Logistics turn-over: UHF general label (plastic case) or UHF anti-metal label (steel tray) with a handheld batch count.
- Room cabinet/ server: UHF Anti-metal label, metal environment required.
- Electricity equipment / outdoor assets: Hard label + IP67 and above protection, temperature resistant to ultraviolet.
- Chemical packagings / Metal pipe: Hard metal resistant labels, some of which require a LF-bed.
Common pit: Wrong one, three months.
The most common errors in the inventory project were largely the lack of a previous period to map the situation:
- Just the parameters, not the scene.The laboratory reads the workshop labels at a distance of 8 metres, and it is possible that only 1 metre will be left on the metal worker's load at the scene, with the count being cut in its own right.
- Neglect of liquid and metal interference: Bottled liquids, chemical materials, dense metal shelves, UHF general labels with weak penetration and must be resistant to metal programmes.
- Not considering the temperature and chemical corrosion.The workshop oil-contaminated, acid-cleaning environment, with normal PET surfaces falling in months and asset data missing.
- Reader and Tag Protocol Not Match: UHF regional standards differ from ISO 18000-6C, EPC Class 1 Gen2, equipment purchased across regions may not be in line with frequency bands and labels are read to mean white reading.
- Ignore Paste LocationThe presence of a covert back of the asset, a metal stitch and a close to a high temperature heat source will significantly reduce the reading rate.
Proposal for action: Three things before the selection.
If you are preparing an inventory of RFID assets, it is recommended that this be done in this order:
- List of assets: quantity, surface material, environment (indoor/outdoor/ workshop/cooled tank), single-unit value, count frequency.
- On-site sample.: Take 3-5 candidate labels, measure reading rates and distances in the real-posted position, and then file the data.
- Confirm Reader/Rearend System Protocol: Labels, readers, ERP or asset management systems are used to access the tripartite data format and avoid later integration pits.
There is no universal RFID tag choice. Fit the tag to the asset and operating conditions, not the other way around. Detailed questions about the application and thorough sample tests are more useful than a hundred pages of product literature. In past projects, Shanghai Zejie has generally toured the warehouse, server room, or workshop with the customer before recommending specific tags and housings. The resulting setup usually works without rework.

Ms. Lei
Mr. Pang