Unsourced rfid tag working principle: radio frequency coupling and energy transfer total resolution
Let's get this straight.
The passive RFID label itself does not have a battery, and all its energy comes from the radio frequency signal sent by the reader. Reader's antenna forms a mutilated electromagnetic field around it, and then the tag antenna enters it with a coupling "interception" of part of the energy, and wakes up the chip, which then transfers the data to the re-reflector signal. The whole process is "reader power + label reflection," which is not allowed without any of the rings.
It is understood that all the frequency band differences, distance limits and antenna design problems in the back can follow a logic.
Radio-frequency coupling in two routes: electrons and electromagnetic reverse disspersion
The different coupling methods used in different frequency bands determine how far and how long the label can run.
Electric connection.The main service is the LF (about 125-134 kHz) and HF (13.56 MHz). Reader ' s and labels ' coil are like the primary, secondary, magnetic field changes that transmit energy. This approach is close, usually not more than 1 metre, but because it works in a nearby area, which is relatively good for the interference of liquids, metals, close to the scene, so door-to-door bans, ID cards, laundry tags, are always using the HFC program.
Electromagnetic Reverse DispersionIt's the dominant way of UHF (860-960 MHz) frequency bands. Readers launch remote electromagnetic waves, label antennas receive signals, and chips adjust the range or phase of a reflection wave by changing their own input resistance, so that readers can "decipher" data from the reflect wave. This way energy transfers and signal returns share the same antenna, are connected to more efficient, read and write at 5-10 metres or even further, storage logistics, retail disk counts use the UHF.
Where does energy come from: the "power-trigger" link inside the label?
The label was "lighted" and it was invisible, and there was actually a power-conversion link running inside.
- The antennas will pass the radio frequency signal.Match Network, match the resistance to the chip or the energy reflect back to waste.
- Signal in.Quick-flowing circuits.(usually a bridge-to-stream of several diode tubes plus one energy storage capacity) to convert the traverse frequency into a direct current voltage.
- When the direct current reaches the chip.Start threshold(The industry usually has around 1.5 V, with slight variations in the chips) and the logical circuits, modems, and memory within the chip are activated.
- When the chips start working, they will consume more currents, so the capacity of the energy-storage capacity, the efficiency of the currents directly determines whether the label can be "awakened" or not.
The chips themselves are usually very small, and they are common in microwatts to milliwatts, but the instant demand for currents is more critical. We've met some early samples in the project, which can be read by a reader, and drop off 10 centimeters away, probably because enough is left to start.
How do you get the data back to the reader?
The energy problem is solved. How do we get the data back?Reverse Scatter Mode.
The chip control antenna input resists jumping between two states: one that allows the inflow wave to be absorbed as much as possible (equivalent to "0"), and the other that allows the injection wave to be reflected as much as possible (equivalent to "1". Reader continues to eject the carrier, labels reflect only a part of it, and then decipher the phase or range change of the reflection wave.
The main UHF frequency protocol, EPC Class 1 Gen 2 (i.e. ISO/IEC 18000-63), provides for this AAK or PSK mode of design. Its advantage is that labels do not need to launch their own radio frequencies, just move "the reflecting wave, which is extremely low.
Several variables in the actual project that influence reading and writing distance
Theoretically, it runs 10 meters, and is probably only 3 meters. This is the most asked question in the project.
- Reader power and antenna gain. Countries limit UHF transmit power, generally to 2-4 W EIRP. Exceeding the applicable limit affects certification. Higher antenna gain concentrates the beam and uses energy more efficiently.
- Tag antenna size and gains. The larger the antenna, the more rational it is to design the gain, the more energy you intercept. The UHF tag antenna usually appears at 3-5 cm, which is a compromise for energy collection and radiation efficiency.
- Frequency range matches wavelength. The length of the label antenna is typically around 1/4 wavelength (UHF has a physical condensation length of about 16-17 cm, which can be reduced by medium), and the energy conversion efficiency of design deviations is sharply reduced.
- Environmental interferenceMetals reflect the frequency, liquid absorbent frequency, human body and paper box stacking. The usual boxes and plastic pallets in storage have less impact, but metal shelves are often organized at a distance of half.
How do we choose the difference between different frequency bands?
The selection should not be based on a mere list of parameters, but on a business landscape.
| Frequency bands | Typical frequency | Concord Method | Typical distance | Typical scene |
|---|---|---|---|---|
| LF | 125–134 kHz | Electric connection. | <10 cm | Animal marking, engine protection |
| HF | 13.56 MHz | Electric connection. | <1 m | House arrest, bus pass, books, laundry. |
| UHF | 860–960 MHz | Reverse dispersing | 1–10 m | Storage, retailing, logistics, asset management |
Use HF at short range, through liquids, or close to the body. Use UHF for long-range bulk counts where orientation sensitivity is acceptable. LF still has a role in low-volume, high-value applications because of its mature supply chain and tolerance for harsh conditions.
A few pits that can easily be stepped on by the landing link.
We have seen several typical cases in Shanghai's quick-looking project, which are listed as a way to avoid pits early:
- The chip is running too low.. The sample phase is well read on the desktop and is then posted to the cargo, with a direct reading distance cut off because of different media, the equivalent antenna alignment point.
- The metallic face is not being handled.. Normal UHF labels are barely readable on the metal surface and must be designed with a specific metal label with bubbled cotton in the metallic compartment or an anti-metallic antenna structure.
- reader Unmatched direction of antennas and labels. The signal decay can be greater than 20 dB in the direction of the line polarized antenna, and a circular polarized antenna is recommended in the dense scene.
- Collisions when multiple labels read at the same time. The protocol layer has a collision-proof mechanism, but when hundreds of thousands of labels are stacked together at the same time, it is necessary to match the group count and appropriate Q value settings for the reader.
- Temperature and long-term reliability. The passive label has a long theoretical life (the label itself does not consume electricity), but welding quality, age of sealed glue, prolonged exposure to UVs or high temperatures can cause performance to decline.
General steps for selection and validation
And finally, we'll give you a routine of our running down to help you do the Tusso:
- Clear scene: distance requirement, number of readouts, attachment media, environmental disturbance.
- Select frequency bands and protocols: HF select ISO 14443 or ISO 15693; UHF choose EPC Class 1 Gen 2.
- Samples are taken: reading distance is measured under the worst conditions (metal mask, near liquids, dense stacking) and not only empty environmental data.
- Small batch test: labels are tangled, fit-in methods, and the location of the reader is verified.
- Consistency tests are done before bulk go online: chip consistency, antenna alignment, and reader consistency are all over to be stable.
The principle of passive RFID is not complicated, but engineering details often determine whether it can really be used in your scene. After looking at this link, you can ask the idea when you talk to the supplier about the program next time.