The RFID fixed asset inventory is appropriate for the large number of assets, their relatively fixed location and the time-consuming manual check-by-case. The focus of implementation is not simply on increasing the number of readings, but on establishing an accurate asset desk account that will read, review and process anomalies by region in bulk, ultimately aligning system records with physical status.

Reassembly one: first, clear inventory scope and asset master data

Before the inventory is started, freeze the current inventory range, specify the area, asset category, responsible person and deadline. The owner of the asset should include at least an asset code, name, specification, department, storage area, manager, state and label number. Without these fields, it is difficult to determine which sector the asset belongs to, even if the label is read on site, whether or not it should appear in the region.

The label code is to be linked to the asset code on a one-to-one basis, and cannot be ad hoc aggregated with "Equipment name plus serial number". For the same model, the separate number of each asset should be maintained for the same batch.

Fields Implementation requirements Common problems
Asset code Consistent with financial or asset desk accounts The field label number is not consistent with the system number
Storage area Detailed to floor, room, shelf or workshop Only registered to the department, and it's impossible to judge where it is.
Asset status Distinction between use, idleness, maintenance, loan and end-of-life Unusual assets were miscalculated as losses.

Redisposal II: Tags and devices are configured according to field conditions

The RFID label is read by the device, which is shown by wireless means, and the position of the label and material directly influence the reading stability. A normal paper label is suitable for non-metal surfaces such as plastic, wood and boxes; metal cabinets, machine beds, server racks, etc., should choose a label that fits the metal surface. More liquids, complex equipment casings or high temperatures, dust areas need to be tested in situ before identifying the type of label.

The label should not be attached to batteries, heat vents, powerful electrical components, which can remove the shell or easily frictionable position. The fixed asset label should normally be placed on a side that allows for review, ensuring that the asset code is visible at close artificial distance and avoiding being covered by door plates, packaging or mask. Before each batch of labels is officially activated, it is recommended to draw no less than 20 distances, angles and blockage tests; this amount is part of the application of the sample proposal, which does not represent industry statistical conclusions.

The power of the inventory device, the antenna direction and the reading mode are set in conjunction with the scene. Open office areas can be covered by a wider range of coverage, dense shelves, adjacent rooms or metal equipment areas should be reduced by invalid reading and the scope of operations reduced. Read distance cannot be sought more than further, and whether it is possible to determine exactly where assets belong.

Rediscretion III: read in bulk by area, not sweep the device around without purpose

When actually implemented, it is recommended to follow the order of "divisions-construction tasks-volume reading-on-site review." The office area, warehouse, room, production line and maintenance area are set up separately for an inventory mission, with each area being preserved.

  1. Before entering the area:Identify mission names, area code and inventory personnel, and check the equipment ' s power, network and label readability.
  2. Batch reading:(b) Move along fixed routes at a relatively stable rate; re-read the antenna angle when encountered with a metal-intensive area, wall or closed cabinet.
  3. Confirm immediately that:The system displays the number of labels and provides close-range review of assets that are not identifiable, duplicated or not in a position to match.
  4. Area closure:Maintain regional records, indicating uninhabited rooms, lock-ins and assets that cannot be judged for a while.

Read routes are best drawn before the count, so as to avoid humans going through and through. For an office with dozens of assets, you can scan the door, against walls, at-sites and in-story segments; for shelf areas, you can sort them by shelf line or store. The speed is based on field tests, and cannot be applied directly to a fixed hourly reading amount because label density, material content, blockage and area size change the result.

Rewind IV: Discrepancies are treated in a group and then decided how to change them.

When a mass reading is completed, the system usually produces a record, undisclosed, an abnormal position, repetition of labels and tab failure. The difference cannot be directly equal to loss. First, you compare the results with the original table, then you verify the reasons by taking live photographs, receiving records, maintaining records or lending documents.

Type of variance The way of judgement. Process Action
System is in place, not read on site Manually search and confirm whether the loan, maintenance or closed space is being lent Filling;to enter the approval process after loss is confirmed
Live read, system unrecorded Reconciliation of asset codes, procurement information and historical desk accounts Pending recognition of assets not directly incorporated into official desk accounts
Tag exists, does not match Confirmation of redeployment or cross-regional use of assets Reproduction of redeployment information and updating of location
Multiple labels of the same asset Check if old labels are not disabled or duplicated Keep valid labels and cancel invalid bindings

Differences are handled by maintaining evidence of the process of “original results—review records—approval of conclusions—check-stand changes”. The changes to the desk account do not cover the original inventory records, suggest additional changers, modify times, modify pre-contents and reasons for changes. This way, in subsequent audits or re-takes, can restore how the differences were created and processed.

Round five: Small-scale patches determine whether the final result is credible or not

Once the block is ready for bulk reading, three types of asset should be filled: the system displays unread assets, assets with an unusual location on the ground, and labels are blocked or unstable. The fillet is confirmed by close range, different angles or manual scanning, etc., and assets that remain unidentifiable are created separately to be processed.

Suppose an office has 120 fixed assets and a bulk scan shows 112. Don't immediately record eight shortages. Check for stray reads from nearby rooms, checkout records, equipment inside cabinets, and damaged tags. Then classify confirmed results as 'found, update location,' 'checkout documented,' 'replace tag,' or 'not found, verify.' This illustrates the procedure; it is not a real customer case or statistical result.

Shanghai-based Select Tech, when designing the inventory process, is better placed to treat equipment reading results and asset performance in the same list of discrepancies, rather than to export only one labeled quantitative statement. For managers, a really useful result should answer three things: which assets have been identified, which assets need to be filled, which account information needs to be modified.

Rewind Six: Deposition of the count as the next reusable rule

After a single count, it is recommended to form a regional inventory record, an unusual asset list, a label replacement list and a desk account adjustment record. The location, label type, device parameter, person route and patching cause are easily missed, and can be saved, and can be used directly at the next count, without retraceing.

The focus of the implementation of the RFID fixed asset inventory is to define the scope with accurate master data, complete a mass reading with appropriate labels and readable methods, and explain differences by filling and approving. You can first select an area for small-scale testing, validate labels, equipment parameters, read routes and categories of discrepancies, then extend to all assets, which is usually easier to control than direct full implementation.