How does RFID power asset management work?
RFID Knowledge

How does RFID power asset management work?

PublishedShanghai Zejie Smart Technology Co., Ltd.

Thinking of RFID as a "high bar code" underestimates the amount of power it can do.

Many people think that RFID is used on electric appliances, which is "sweeping Zinventory counting." This step actually reduces the most useful use of RFID -- the power industry's control over safety devices, which is essentially a retrograde whole life cycle of every tool: from access to regular testing to end-of-life, with each change in status documented and someone responsible. The meaning of RFID is to put information that has been scattered over paper and human memory, pinned down to every specific item.

The equipment at the power field -- insulation gloves, wires, electrical appliances, safety belts -- is almost identical, but each of them may be much different: some have just had a stress-resistant test last month, and others are long overdue. Without identification, it's all eye-detected and self-conscious registration that leaves a security problem. Each tool is marked with an electronic label, which is equivalent to an identity card, any one of which is handed over, tested, scrapped, and can be traced to the system.

Safety control of equipment, what does it matter?

When you go to the site, the tools are managed in approximately four blocks: register in a library, take it on a daily basis, test it regularly, and fail. If you add only paper documents to manual inventory, these four pieces are often in the middle of two loops -- after the tools have been borrowed, where, how long, how long, how long they were back, without continuous records.

For example, the insulation gloves are subjected to a six-monthly preventive test, and safety belts are subject to a static load test every year, and each time they are used, the surface is checked. In RFID, these cycles are tied directly to the electronic code of each tool, which is close to the automatic alarm when it expires, and over-period uninspected tools are stopped at the access point. This is much less reliable than "Booking the record book by the day."

Three basic tasks that can't be saved.

RFID tags and reading and writing devices, how to choose at the power field, how to make it.

The electrical appliances are mostly metal-shell, rubber material, and work environments with oil, temperature and ultraviolet light. The label requirements are much higher than normal logistics scenes.

Tool Type Recommended Tags Read-and-write devices
Insulation gloves, helmets. Soft Anti-Metallic Label Fixed Reader (UHF)
Groundline, electrical casings. UHF anti-metal labels for epoxy seals External Channel Reader
Fieldwork, site repair. Ibid. Handheld terminal (recommended IP65 level)

Fixed-form readers are usually placed in front of the tool room or cabinet, with a distance of 3 to 8 metres and automatic access recognition; handheld terminals are suitable for large, dispersed locations, but flexible enough to be cleaned on the initiative of people.Shanghai Picking Up Tech Ltd.When you land, you usually do a round of field-frequency surveys -- measuring the reflection of metal on signals, confirming where antennas are installed -- that often determines whether the whole system is stable. The radio frequency itself does not work, and environmental interference is an undervalued link.

How do you connect the data to the existing system and which pits can be avoided earlier?

The RFID label itself is a "id" number, and the real management value is at the back end. There are three types of interconnection that are common: an independent equipment management system; mobile applications for EAM (Enterprise Asset Management System) or PMS (Property Management System); and a mobile application for shifts, which is used by teams, a work ticket system. Either way, several fields are indispensable: only one number of tools, specifications, date of acquisition, current status (in the library/under examination/end of life), next trial date, last operator and time. The field and actual business processes are consistent to actually move, not another "demonstration system" for inspectors.

The easy-to-penetrate pits in operation are concentrated in three places.The label selection does not take into account the metal environment— Normal paper labels on metal surfaces, which can be significantly reduced or even not read, are determined by physical principles and require the use of anti-metal labels or design labels to avoid the location of metals.Readers are in "scrutinized" rather than "reasonable".— Interruption of metal doors or shelves is taking place, and it is often more efficient to adjust antenna angles and power than to replace equipment.First-line teams think the new process is "problem."– One or two minutes more, and someone will go around, either by making automatic contact recognition or by simplifying handheld to one or two buttons. The system is pushed unsustainably, often at this last mile.

Back to the core: RFID is about security, not convenience.

And one of the root causes of many accidents in power operations is that the tools themselves are "unsafe" -- uninsured, defective and unsegregated, misused at an undesirable level of voltage. RFID can't directly eliminate these hazards, but it can make any instrument's state quickly, accurately traced, from "post-back" to "pre-interception."

If you're assessing whether to go on this system, you can ask three questions: first, is the number of safety devices in this unit so much that they are no longer able to handle the paper billboard; secondly, if you can pull out a full-cycle record of any tool within half an hour at the time of regulatory inspection or internal audit; and thirdly, if there's a complete closed loop when the tools come back from the tool room. Two of these answers "Yes," the benefits of the RFID are worth taking a serious accounting. The tool management seems to be the small thing, often the highest output in power security management.