How can the management of power system assets be achieved? Tool and asset security controls
The power system's assets are not easy to handle -- a main transformer could be worth tens of millions, a high-pressure cable would have to patrol dozens of kilometres, and a transformer would have to number thousands of parts. Faced with this scale and value, many struggle: should we continue to use Excel or the previous set of specialized asset management tools? The criteria are not complicated: looking at the amount of assets, the regulatory requirements, whether security risk control is involved.
Cost dimensions: input gaps from one table to one platform
The cost of managing electricity assets is often underestimated. Many people think "buy a software" is actually not just about the authorization fee, but also about manpower, implementation and later maintenance.
Lightweight scheme (electronic bill + scrutinizing): Use a local server or cloud hosting, with 50,000–150,000 yuan in initial infrastructure costs. Build the software on an open-source or low-code platform; licensing typically costs under 100,000 yuan. One or two people maintain the asset register, mostly through manual entry. This suits small and midsize distribution rooms or sites with fewer than 500 assets.
Medium programme (Professional EAM, i.e. enterprise asset management system): Software licensing typically costs CNY 300,000-1.5 million, depending on the number of modules. Implementation usually costs 0.5 to 1 times the software fee. Set aside an additional budget if you need integration with supervisory control and data acquisition (SCADA) or enterprise resource planning (ERP). Ongoing operations and maintenance require dedicated staff and cooperation from the business departments.
Heavy programme (digital twinning + physical networking platform)(b) Investment is at millions of levels, suitable for provincial grids and large power generation groups; it is usually long-term, with stabilization effects in 1-2 years.
Shanghai-based Chettech, while serving industrial customers, found that many electricity users initially took the lightweight option, doubled their assets in the second year, had to move to a professional system, and had to migrate to a different level. It was suggested that expansion costs be set aside at the planning stage, usually on a 30-50 per cent basis of basic inputs.
Effect dimension: What can tools solve, where borders are?
Asset management tools are not everything-powerful, and their capabilities are clearly defined before they fall into the ground.
The tools can be used to do things that are good:
- Digitize the equipment register and give each component a unique code, usually on an RFID tag or in a QR code. A scan retrieves specifications, location, and service records;
- (b) Standardize the inspection process, whereby inspectors follow the pre-defined route and the leak detection system automatically alerts the police;
- Maintenance of automated archiving of records, including time for overhauling, replacement of spare parts, responsible persons and operational content;
- Life expectancy: Based on operational data and history of failure, extrapolate the remaining useful life of equipment and recommend replacement.
Tools do bad things:
- The final diagnosis of the internal failure of the transformer is based on specialized techniques such as oil chromatography, and stationary testing;
- Directly reduce the failure rate of equipment. The tool is essentially "seeing assets", not "fixing them" ;
- Auto-rehabilitate network security gaps.
Practice data from the domestic and foreign power industries show that when asset management systems are online and functioning steadily, the average time between equipment failure (MTBF) usually increases by 10 to 30 per cent, provided that the process actually runs up, not the system becomes "high-level desk account."
Application scenario: how different assets choose different tools
The power assets vary widely, and the choice of tools cannot be made in one way or another.
At voltage level:
- (a) Super-high / high-voltage transmission: high value and impact of failure, with a recommended professional EAM+ online status monitoring to ensure that each major transformation and every line has an independent file;
- Moderate voltage distribution: the equipment is large and widely distributed, suitable for a combination of GIS+ mobile inspection, with inspectors holding the terminal on site;
- Low pressure / Household: mainly meters and distribution tanks, with meter data management (MDM) system, without heavy asset platforms.
By size of organization:
- Large grid enterprises: usually self-built platforms, integrated management, and deep integration SCADA/EMS (energy management systems);
- Industrial parks or large factories: select mature EAM products, with a focus on the interface with existing MES (manufacturing implementation systems);
- Small power distribution room: First, the electronics are properly accounted for and the process is running smoothly before being considered for upgrade to a full system.
By security level:The power assets involving key users, such as military engineers, railways, hospitals and data centres, are not only for the equipment but also for "who can access it and what to do" - this is within the scope of asset security control.
Common pits for asset security control
The security of electrical assets is not just a prevention of theft. It has three dimensions: physical safety, operational security, and network security. Each level has a pit that can easily be stepped on.
Physical safety:
- "Stamped" equals "manipulated assets." The RFID tag can be torn off, the two-dimensional code can be replaced, and key nodes require electronic fences or closed doors;
- Spare parts warehouses are delinked from the accounts of the equipment in use.
- The disposal process for decommissioned equipment is missing. Old transformers, switch cabinets and secondary markets are common channels of asset loss.
Operational safety aspects:
- Over-reliance on state monitoring data, neglecting cyclical tests.
- The maintenance plan is not followed up. The system is assigned to tasks, but is not linked to performance and is finally in vain;
- The record of the overhaul is not standard, "retarded" does not mean "fixed", and subsequent analysis is prone to miscalculation of the equipment's state.
In the area of cybersecurity:
- The asset management tool, if deployed on the Intranet, requires strict segregation and cannot be accessed directly from both directions;
- Third-party maintenance staff have too much authority.
- Ignores the administration of solidware and software versions. The old version of SCADA, PLC (programmable logic controller) is a high-growth entry point for cyberattacks.
The most common reminder in Shanghai when it comes to assessing the security of its clients is that security controls are essentially "who can do what and leave behind what", and the tools simply do things.
Back to the first option.
The core of power asset management is to move from "man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-man-woman." When you select the tool, you think about three things: size-of-assist, security requirements, maturity of existing processes. You don't have to pursue a big and full start-up phase, go in two modules of the equipment table + check process, run through and expand.