How can the RFID fixed asset inventory be implemented? On-site operating norms
Industry News

How can the RFID fixed asset inventory be implemented? On-site operating norms

PublishedShanghai Zejie Smart Technology Co., Ltd.

At six in the morning, handheld terminals are beeping throughout a factory warehouse. Three inventory workers line up along the shelving as tagged asset bins pass through the portal one after another on a conveyor. In less than 40 minutes, they check 2,300 pieces of equipment against the register and find only seven tag exceptions. This is what an RFID fixed asset count looks like with proper preparation: fast and accurate. Without it, the same warehouse could take two days.

Let's take a look at the scene. Don't be too anxious to label it.

Many projects are being planted on "No Step Up to Dry." The inventory of RFID assets is not labeled, and the labels and the environment are a pair.

We usually send an engineer to the scene for a walk, focusing on four things:

The site report, which is the basis for subsequent acceptance and which contains a problem of missing readings, is a reference to the suggested label specifications, location of the reader ' s placement and attention in each region.

Label Selection and Encoding Instructions, Do not drag a label down the whole data

The RFID tags are used three common frequencies: low frequency (125 kHz~134kHz), high frequency (13.56 MHz), UHF (860 MHz~960 MHz).UHFBecause it is far away, can read hundreds of copies at a time and has a clear efficiency advantage.

The coding code is easily ignored, but it's a problem. In every account we make for each client, the EPC code (Electoric Production Code, the only identity code stored in the tag chip) usually follows this rule:

Fields Length Example: Meaning
Company Code 3 places ZJ0 Distinction of business
Asset class 2 places 02 e.g. 02 for production equipment
Database year 2 places 24 2024 Brief
Water Stream 6 places 000123 Order of year
Verify 1 Bit 7 Incubation error

Once the code is finalized, do not change the format halfway. The change will be costly and will be followed by all handheld terminals, intermediates, ERP (ERP system) interfaces downstream.

Label pasting: Position is more important than glue

The same label, with different positions, can be read at two or three times the difference. We have summarized a few of the more general principles:

After this, each label is tested on a live writer to confirm that it can be read and read until it is considered eligible.

Encoding Writes and Ties to Desk

The label will need to be installed in the system, with EPC encoding, asset name, specification model, use department, location, date of purchase, amount of information. This is usually done by hand-held end code, post-label pop-in interface, sweeps the bar codes or manual fill-out on assets, and synchronizes data after submission to backstage.

The particle size of the account field is clear in advance. Fields are too few, and will be difficult to trace; fields are too many, and entry efficiency is down, and they can be made wrong. The more balanced approach we have seen is that core fields 7-9 must be filled, extended fields 10-15 should not be saved without all the entries.

The construction of the live inventory tunnel.

The most critical equipment on the site on the day of the inventory is a reader and antenna.

Fixed access door– Two to three pairs of antennas, with a width of 1.2 to 2 metres, suitable for the frequent movement of assets and the need for long-term monitoring. The advantage is that one deployment is long-term, the disadvantage is that initial installation requires low power construction, with a deployment cycle of two to three days.

Move Handheld TerminalThe inventory operator is taking the PDA along the shelf, with a normal distance of 3-6 meters, and can read 8-10 meters in the direction antenna. It's a suitable scene for dispersing assets, unwieldy wires, like office areas, laboratories, outdoor stacks.

We generally recommend that both of the clients should be matched: a fixed access door is responsible for automated recording of daily in- and out-of-the-port assets, and the end is carried over every quarter or year. Both data are aggregated on the same platform and the long-term entry is fine.

How do you adjust the reader parameters?

The default parameters for the exit are often not used in situ and need to be fine-tuned to the environment:

There are no standard answers to these parameters, and each site is subject to a small test. The test takes 50-100 labels in hand, simulates normal operating scenes, records the full reading rate, three times in a row, over 99%.

Processes for on-site scanning operations

On the day of the official inventory, it is suggested that we proceed in the following order:

  1. 30 minutes before the job, all countrs meet before shift to confirm the day count area, the equipment power, the tag backup.
  2. Handheld terminal login, downloading the day-to-day inventory and verifying the integrity of offline data packages.
  3. Scan in batches by area, each shelf channel stays 5-8 seconds to ensure that the label is read out.
  4. Separate location numbers are recorded for the system marked "unread" assets and manual review is scheduled back.
  5. Once all the regions have been scanned, terminal data are uploaded to the backstage to generate discrepancies reports.

In practice, a trained inventory clerk with one handheld terminal can reliably scan 400–600 assets per hour. A three-person team working in separate zones can finish 2,000 assets in half a day. This is four to five times faster than using barcode scanners and paper forms, with an error rate below one in a thousand.

Handling of abnormal labels

The labels that you cannot read are encountered in the inventory for four common reasons: damage to the label, loss of the label, insufficient capacity of the reader and blocking of the label.

These anomalies cannot be temporarily processed, and are recorded in the inventory abnormality register, where they are, for reasons of processing, for reasons that they are filed after they have been filed. The "processed" and "unprocessed" items in the account are clearly divided, or the next round of the inventory must be repeated.

Data reconciliation and variance analysis

The inventory is not just "sweeped" but data reconciliation after the sweep is the focus. The RFID system reads the EPC code list, which compares it with the ERP or financial system asset desk accounts and identifies three types of differences:

After the discrepancy report, it is recommended that the first line department be given a three-day review period to enable the user office to confirm the actual situation of its assets. Three days later, the difference remains unclosed and is submitted to asset management for final decision. The whole process leaves a mark that the end-of-year audit can be accessed directly.

Duplicate and maintain after the count is completed

The end of the count is not the end of the project. We usually do a back-up meeting to sink the data from this operation:

RFID labels are not a one-time waste, but they are not a permanent device. A normal paper label can last three to five years, and anti-metallic labels can last five to eight years, and the ducts will be affected by oil and ultraviolet light, which accelerates ageing. It is recommended that tag inspections be conducted every two years, and that the edges be found, and reading distance be changed in time for a significant drop.

And to take these steps apart, one step is not complicated, and the difficulty is to connect them. From a step-by-step, code, paste, walk-in, scan to data check, each step leaves clear deliverables and time nodes, the count does not turn into a battle. Shanghai-based technology runs through projects like this in multiple manufacturing, storage, office scenes, the most significant feeling of running down is that RFID's speed advantage is obvious, but stability is better than just a little pile of pre-regulating, and the more regularity of operations is the more the job, the less the balance of each round of post.