What is the rfid tunnel machine for, mass reading and deployment?
RFID Knowledge

What is the rfid tunnel machine for, mass reading and deployment?

PublishedShanghai Zejie Smart Technology Co., Ltd.

The RFID tunnel is suitable for label-intensive, mass recognition scenarios -- all of the points it can use are distribution centres, clothing storage, book flow back and offline. Can you run steady, see if the core has three things: whether the antenna layout, shield structure, and nodal control match. Either chaining goes off, reading drops from 99 to less than 80%.

Let's see if this is worth the tunnel.

Tunnels don't fit anywhere. When we do our projects for clients, the first step is to ask three questions:

All three conditions are met, and it makes sense to talk about specific programmes.

Batch reading solves three things: missing, stringing, quick reading.

The core value of a tunnel machine is to read all labels of the whole box or whole-ton cargo at once.

Missing.The common reason is that the labels are not consistent or masked. The solution is to have 4-8 sub-rays cross-covered on both sides of the tunnel and at the top; the box stays long enough in the tunnel to allow all the heading tags to be read. The normal box length is 50-80 cm, with a speed of 1.5 m/s, and the single-box viewing window is about 300-500 ms, which is enough time for many antennas to complete a scan.

Threading.When the first box is too close, the previous one's label is read in the back of the box, which causes an error. The infrared light at both ends of the tunnel is used to trigger the "read this box" switch -- the box is fully entered and the upper one is completely out of the box before reading it. The two boxes are more securely controlled at 50 cm or more.

Quick read.Multiple label impact-resistant algorithms (based on the dynamic time slot distribution of the EPC Class1 Gen2) are key. The mainstream UHF readers chip can handle 200-400 labels per second, which is generally sufficient; but when a box exceeds 300 labels, it takes into account the split reading or double frequency combination options.

The deployment phase is a few points that can easily be matched.

Hardware is only the beginning, and what really determines the project's success or failure is the details of the site. We are following in these places and write it for your information:

The shield structure is not solid.If the RF absorbers or metal curtains at the two ends of a tunnel are inadequate, signals can leak through the openings and read tags at the preceding and next workstations. The absorber's frequency response must match the frequency used (920-925 MHz for UHF in China). It is typically at least 20 mm thick. Incorrect installation or skimping on material will cause inconsistent read rates.

Metal and liquid interference.Metal trays, liquid beverages, aluminium packagings cause the label to significantly decay. A customer who does a solar chemical, has a plastic sheet out of the box, labels on the inside side, reading distance is dropped in half -- then the labels are changed to the outside side, and problems are solved. These problems must be physically tested before acceptance, not just empty case data.

Wire and power.UHF antenna feed lines are sensitive to length. Runs over 5 m introduce significant loss and require low-loss cable or an amplifier. Reader power fluctuations also affect reliability. Use a dedicated power supply instead of sharing a circuit with motors or variable-frequency drives.

Label consistency.If the label chip brands or models are mixed, the adjusted antenna parameters will work only for half of the labels. It is our habit to nail the label selection at the beginning of the project and do a small batch physical verification.

How do you get involved in the acceptances?

The three-step approach proposed for the reference phase is:

  1. Space Test— No cargo, observation of signal cover maps in tunnels, confirmation that there are no visible blind areas.
  2. Full box test.— Run 500-1,000 items in real containers, record the number of times each label is read and RSSI values are filtered out of RSSI labels below -60dBm, which can easily be omitted from the production line.
  3. Pressure testRun continuously for at least four hours and check whether cycle time and missed-read rates remain stable. Reader power can drift as the unit warms up, and an extended run helps uncover it.

For acceptance, set a read rate of at least 99% for standard items. Log the proportion of exception items, including metal and liquid items, and the reason for each missed read for later tuning. Include read time, per-case processing time, and missed-read alerts on the checklist rather than looking only at the final total.

The process is basically a matching exercise when Shanghai Picket Tech Ltd. is serving the distribution centre and clothing storage customer. The client last took not a tunnel machine, but a mass identification program that can run.

Back to the core: what kind of scene is worth investing in?

And then, over and over, the RFID tunnel machine is putting out the highest output scenario: labels are dense, flow to fixed, and there are continuing production or logistics requirements for rhythm. These types of tunnels can replace a large number of manual scans, pressing single-case processing down to 1-2 seconds.

In turn, if the scene is mixed, moving in high and high-speed rhythms, it is difficult to recover costs by forceing to go to a tunnel. It is recommended that a small pilot be done, a month or two of data before the data are spread.

The RFID tunnel is not deployed with a single device. It is a system project for antennas, shielding, metronization, labels, backstage connections.