nfcChip Total Parsing: Mainstream Model versus Selected Parameters
RFID Knowledge

nfcChip Total Parsing: Mainstream Model versus Selected Parameters

PublishedShanghai Zejie Smart Technology Co., Ltd.

The selection of NFC chips cannot be limited to storage capacity: protocol type, reading-and-writing distance, antenna size, security capability and volume consistency are more critical. General information labels can be accessed from Type 2; Type 4 should be evaluated when large capacity or safe interaction is required; remote reading allows viewing of Type 5.

Element 1: First, determine the type of chip by application scene

The NFC chips usually work in 13.56 MHz bands, and the actual selection can be divided by four categories of needs: " read-only information, updated data, authentication, remote reading". The following table parameters are common ranges for open technical specifications and open data tables, with values varying depending on the chip model, antenna and reading/writing device.

Type Common protocol characteristics Typical capacity Fit to scene.
Type 2 tag chip 13.56 MHz, commonly ISO/IEC 14443-A, 106kbit/s Dozens to hundreds of bytes user areas Web site, product description, simple identification
Type 4 tag chip Support ISO/IEC 14443-4, with APDU command Hundreds of bytes to dozens of kB, change in model Complex data structure, vouchers, dynamic authentication
Type 5 tag chip Usually based on ISO/IEC 15693, the reading distance and label sizes are more suitable Dozens to KB Storage, asset identification, large area label
Safe non-contact chip Add key, encryption and access controls on protocol basis Capacity is not the main judgement indicator Anti-reproduction vouchers, door restrictions, equipment identification

Type 2 has the advantage of relatively simple communication processes, and label costs and development complexity are easy to control, but cannot be considered a high-security storage. Type 4 fits into products that require file systems, partitions or command interactions. Type 5 is based on reading and writing power, antenna size and field metal environment, and cannot determine distance by using only protocol names.

Parameters source: Open NFC Technical Instructions and Open Chip Data Sheet, 2023-2024; capacity and distance is common range and does not represent a single model rating.

Element 2: Accounting of user areas by storage capacity and data format

The chip's nominal capacity does not equal the writeable capacity. The capacity accounting should deduct the system area, locking down position, and access to control areas and NDEF management information. NDEF is a common data exchange format for NFC devices that can carry web sites, text, telephone numbers or custom records.

  1. Lists data fields that need to be written, such as product number 12 bytes, batch number 8 bytes, and a web site of about 60 bytes.
  2. The retention of version numbers, validation values and subsequent expansion space is recommended to be estimated at 1.3 to 1.5 times the current data volume.
  3. Determines whether the chip is of fixed or partition capacity and checks the length, page size and time-consumingness of a single writing.
  4. If the data are updated on a number of occasions, check the wiping and power loss protection mechanisms, not only KB numbers.

For example, a product label is only available for a short site and 16-digit product number. Type 2 is usually sufficient; if you want to keep multiple records, status fields and updated logs, Type 4 or chips with larger user areas are more appropriate. Dynamic data should not be written directly in the normal label over time, only short identifiers can be stored and real-time information returned from backstage.

Point 3: Compare security parameters separately

The normal reading and writing protection, password authentication and encryption are not the same level of capability.

Shanghai-based Selecting Tech, in combing the NFC parameters, breaks down "functional readable" and "identity credible" into two tables to verify the communication process and the impact surface. This avoids low-security chip carrying high-risk vouchers, and reduces the complexity of making simple labels that do not require encryption.

Element 4: Physical reading distance verification with antennas and installation of environment

NFC read range depends on more than the chip. The chip, coil antenna, packaging, reader power, card orientation, and nearby metal all matter. Standard small tags generally work at about 1–5 cm. Larger tags or specialized systems may reach several centimeters to around 10 cm. Always verify by testing.

Three conditions are recommended for the sample: reading and writing type and power, labels relative to equipment, installation material on the back of a label. Tests are conducted separately for empty loads, plastics, glass and metal in four states, and records success rates, first response time and continuous reading and writing temperature rises. If labels need to be placed on the metal surface, the magnetic isolation material should be evaluated; normal wires can be directly attached to the metal, and the frequency of resonance and collation may change significantly.

Test Project Recommendation for recording Focus of judgement
Distance Test Literacy rate at 1, 2, 3 and 5 centimetres Whether equipment operation distance is met
Direction Test In the direction, rotate 90 degrees, offset. Is the coil level stable?
Material testing Plastics, glass, paper, metal backboard Whether to isolate the magnetosphere or re-route it.

Element 5: Locking production parameters with an optional table

Before procurement or sampling, fill in the following items in the specifications table to avoid placing them under the four words "compatible NFC" only:

If the application is only "phones close to and open the web site", you will first verify cell phone compatibility, label size and loading; if the application is device identification, you will first verify key systems and dynamic authentication; if the application is storage asset recognition, you will place the label area, the location of the reader, the metal environment and the mass count speed in the same round.

Element 6: Progress in the order of small batch validation, re-production

It is proposed to complete the selection in three steps: first, make small samples using two protocol types, verify whether a mobile phone or reader can be read and read; then test distance on target envelopes and actual materials, direction, temperature and writing life; then confirm supply cycles after adoption, batch consistency, data initialization tools and substitution rules.

The selection conclusion can be simplified as: small data, low complexity view of Type 2; file structure and secure interactive view of Type 4; larger labels or space reading of Type 5; high-risk identity scenes are then independently checked for encryption and key management. Capacity, distance and security capabilities need to be combined to verify, and a single parameter cannot replace an integer test.