How do you select the electronic tag for the fixed assets management system?
RFID Knowledge

How do you select the electronic tag for the fixed assets management system?

PublishedShanghai Zejie Smart Technology Co., Ltd.

First, to conclude: The choice is not expensive. It's right.

Electronic labels are not "best" but "best match." Before choosing, you can keep an eye on three dimensions: the condition of the asset (metallic surface, liquid by-product, high temperature workshop or outdoor open), the method of counting (man-made sweeps, or a mass-readable walkway) and the system interface (can you have a smooth access to your existing asset management system). Clear these three things, the type naturally narrows down to two or three candidates. And then you compare brand names, prices, life parameters that matter. We see many projects that start with a match in the parameter table, and the label that comes back is not read out on the metal cabinet, and is busy.

Let's start with the mainstream.

The electronic labels that are common in fixed asset management today fall into four categories, with significant differences in their respective capabilities.

The first is the UHF RFID label, which works at a working frequency of 860-960 MHz, with a maximum reading distance of 10 metres or more, suitable for warehouse shelves, whole cabinets, and a scene like the car underboard that needs to "go through and finish a lot of the count." It's about being afraid of metal interference, and normal tags are blocked on the metal surface, and reading distances are reduced to a few centimetres.

The second category is HF RFID labels, 13.56 MHz, which typically have a reading range of between 10 cm and 1 m. Typically represent the familiar NFC, with many closed cards, staff cards. It is better than protocol, mobile phones can read, suitable for office equipment, laptop computers, instrument meters, etc., that need to be precise at close range to a single station, and sometimes take a table.

The third category is on-metal RFID tags. These add an RF-absorbing layer or a ceramic substrate to the back of a standard UHF tag so it can be read on a metal surface. Cabinets, machine tools, transformers, and steel racks generally require this type. An on-metal tag typically costs two to five times as much as a standard tag, but on metal there is no practical substitute.

The fourth category is two-dimensional or bar-coded labels, which are essentially visual recognition and do not rely on radio frequency signals. Its advantages are extremely low cost, a few cents per unit, printing; the disadvantages are to scan manually one by one, to wear oil, to wear, to hide, to recognize failure. It suits those positions that are fixed, do not move often, have low assets, such as desk chairs, fire equipment.

Another option is a Bluetooth Low Energy (BLE) tag. It runs on a battery and broadcasts a signal that a phone or dedicated gateway can use to locate it directly. It suits valuable equipment on large campuses and assets whose movements need to be tracked, but costs tens to over 100 yuan per tag. Battery life is typically one to three years.

The job is the real basis for decision-making.

The type is clear, and the next step is to see where your assets are located. The environment tends to have a more direct impact on labels than the indicators in the parameter table.

The plant's CNC machine bed, distribution cabinet, steel shelf, medical equipment shell, where the metal comes in direct contact with the back of the label, the normal UHF tag is basically invalid. We did a CD for a client who did the precision processing, and they initially purchased a set of generic RFID labels on the floor, which were found to have read distance from 6 metres to less than 20 centimetres, and then replaced with all anti-metal tags, so that the problem was solved. The factory then unified all the machine bed assets into a metal tag, and made monthly count with handheld terminals, which raised about 70% of the overall efficiency compared to the previous manual copying table.

Liquids are similar to metals, and they shield the radio frequency signal. The drums, tanks, bottles that are not directly labeled are less effective when placed on the outside of a metal barrel or in a plastic bag. In this case either a plastic pad is added to the label from the metal surface, or a liquid-resistant version is simply chosen.

The working temperature of the normal RFID label is mostly between -20°C and +70°C, covering most indoors. But if it is a cold tank, metal smelter, outdoor open-air equipment, it needs to be selected for heat resistant models, such as high-temperature-resistant labels that typically carry more than 150°C or even 200°C, which can be achieved at -40°C. In terms of protection, IP67 is the basic threshold for off-site assets, with an IP68 able to impregnate for short periods of time, so that the hottest or dusty environment is clearly seen.

One of the easy-to-neglect points is chemical corrosion. Chemical plants, plating workshops, laboratories, labels may be exposed to acid, oil pollution, organic solvents for long periods. Common PET (a common plastic thin sheet) faces will not last long before they start bubbles and fall. This situation suggests that the labels for PP or PI (polypropylene) face, which are then fixed with epoxy resin or industrial reel.

Read distance to match the count

The way you count it determines how far you need to read. Many people are not thinking much about this when they buy it.

If the monthly count is taken, the inventory officer takes a walk around the warehouse with a handheld terminal, and each shelf stops to read out the whole set of assets, which is enough for reading distances of 1 to 3 metres, or picks a normal UHF tag or an anti-metallic label. If the cost is well controlled, a single label can be pressed within $1.

If you want to make a walk-through automatic inventory, without having to do anything, the RFID antenna array that is pushing the shelf through the middle of two doors will read the entire set of assets, at which distance is 5 metres or more, and the orientation of the labels, the mass-reading collision resistance (i.e., whether multiple labels are read in time) will be high. Selectively, special attention will be paid to taged EPC area capacity and writing speed, and the EPC section is the storage unit for the asset number, and it will not be complete if it is insufficient.

If assets need real-time location, like a hospital respirator, or valuable surgical devices, or servers that can be called at any time in the data centre, then it's not normal RFID to solve them by using BLE Bluetooth or UWB (ZZQQZ) positioning labels to track assets in conjunction with the location base station. Both options have unit prices and deployment complexity up a step, and budget and return cycles need to be counted separately.

The system is not going to be easy.

The label is ultimately written into the asset number and bound to the asset management system. There are two common problems with the interface.

One is data format. Many label chip producers defaultly output hexadecimal raw data, while asset management systems have a rule-based asset code, such as "ZC-2024-0058". If you do not have a conversion program, the inventory data entry system is a bunch of unreadable obscurities. The selection phase asks whether the tag chip supports user-defined EPC area code and can be locked in (prevent subsequent error).

The other is fit for intermediate. RFID has a handheld terminal or fixed reader with its SDK (Software Development Toolkit) and API (Data Interface). If you have an asset management system that is self-studyed, the team needs to develop these interfaces; if you use a mature SaaS (Logware Service) asset system, make sure that the system is driven by mainstream RFID equipment. We usually do project integration by sending a reader, label, bulking of the back-stage system, and avoiding online failure to read a particular manufacturer's label.

A few practical experiences.

Do small batch tests and then a large volume of purchases. No matter how good the factory's label parameters are, buy 50 to 100 sample sheets, put two weeks on the worst workspace, read rates, hold up, and have an environmentally resistant environment. Reading is below 95% basic insurable.

Preserve the redundancies of code. The EPC area capacity is as high as 96 bits, allowing for subsequent expansion or compatibility with multiple systems. Fixed 64 bits are cheaper, but they need to be replaced when you want to add a field.

Match tag life to the asset lifecycle. A tag might last five years while the asset is replaced every eight years, requiring retagging partway through and adding work. Conversely, a tag rated for ten years is a waste on an asset that will be replaced after three.

Finally, the deployment chain will be archived for each label. The tag location and asset appearance will be taken when the tag is posted on site, which can be quickly found during follow-up maintenance. Shanghai-based technology works more smoothly in this process in a number of enterprises' assets Zinventory counting.

Back to the beginning.

The core of the electronic label selection is to get the work, the inventory method, and the system to get a clear idea of these three things, and then match the corresponding label type and parameters. Blindly pursuing "Fine" or "lowest" will cause trouble. From the real asset scene, check first, buy later, and keep coding back and the system interface, this road will not go wrong much.