Many people think that RFID can be identified by putting labels on, and the reader is able to do so. The effect depends on frequency bands, how the labels relate to objects, how the antennas are set, how power is controlled and where the electromagnetic environment is in place. Low frequency is for close-range stabilization recognition, high frequency is for short-range interaction, hyperfrequency is for lot reading; the key to resistance is not simply power enhancement, but rather for frequency, antennas, protocol and field equipment.

The rationale for the RFID application: labels are not "active signals"

The RFID system is usually composed of electronic labels, readers, antennas and back-office software. The passive tag does not have an inline battery, acquire energy after entering the reader's electromagnetic field, and then returns the numbering from the chip by load-modulation. The back-office system links the material to the label number, location, batch or state, so the RFID itself addresses mainly "identification and acquisition," which is not naturally equivalent to real-time positioning.

A set of applications can be understood on four levels: labels are responsible for carrying identity, readers for launching and receiving, antennas determine the direction of energy cover, software filters duplicate readings and writes into the business system. The tags can be placed on trays or swingboxes, read in access libraries; labels can be installed at production sites on a workload or material box to determine whether the process is matched with the location of the label and the area of reading. The labels are not designed properly, even if the equipment parameters are high, they may be leaking, stringing or repeating.

The frequency range is different, the distance and the scene are different.

Frequency bands Common working frequency Main characteristics Common applications
Low frequency LF About 125 kHz, 134.2 kHz Closeness, better ability to bypass some non-metal media and lower data rate Animal identification, door-ban identification, specific equipment identification
HF HF 13.56 MHz Close-to-field coupling, with relatively easy to control reading areas, suitable for short-range interaction Cards, books, samples and close tag reading
UHF UHF About 860-960 MHz Read distance is far away and can be identified in bulk, but more vulnerable to metal, liquid and multi-range reflections Inventory of storage, logistics corridors, production lines and asset management
Microwave band Common 2.45 GHz The antenna is smaller in size and has a higher rate but is more sensitive to the shielding, installation and electromagnetic environment Specific vehicle, equipment or industrial identification scene

The frequency in the table is the common range of work, and the specific launch power, the channel and occupancy mode shall be based on the radio management requirements and equipment standards of the project area. The frequency segment characteristics can be used to refer to the ISO/IEC 18000 series standard and its UHF air interface specifications issued in 2015. They cannot be selected only by "reading distance far enough to fit": a close-range single label confirms that priority may be given to LF or HFC; when multiple materials are identified at the same time, the UF is usually more efficient, but must be matched with field tests.

Inverse labels, antennas and installation from identification needs

The selection of the type identifies four questions: how far away a label is from a reader, how many labels are to be read at a time, whether it is on a metal or water-bearing object, and whether the area of reading needs to be restricted. For example, using the UHF storage channel, it can be designed in the order " Label Encoding - Antenna Cover - Channel Blocking - Software Heavy".

When Shanghai-based Sieger Technologies, Inc. is designing RFID applications, it usually uses "the performance of the label on actual material" to be validated before laboratory parameters: a walk-through test with real packaging, real stacking and target channels, recording the labels in the direction, reading distance, missing number, misreading area and equipment working. This process reflects more than just looking at the chip's nominal distance.

Interference is dealt with in four categories.

1. Electromagnetic synergetic and Neighbourly Interference

When multiple readers work simultaneously, there may be a "hearing" between the reader and each other, an overlap of the channel or a strong signal is suppressed. The processing involves dividing the working channel, staggering reading and writing time, reducing power in adjacent devices, increasing antenna spacing, and using suction or shielding material between channels. Multireaders are deployed to read out only one device and should be tested when all equipment is running at the same time.

2. Refraction, absorption and disharmony caused by objects

Metals reflect electromagnetic waves, liquids absorb a portion of energy and walls, shelves, and equipment casings may cause multi-range reflection.

  1. Keep the label isolated from the metal surface and use anti-metal labels when it is impossible to leave space.
  2. Change the height of the antenna, the peri-point and the polarization direction to avoid a strong reflection path.
  3. Reduced antenna coverage and limited reading areas using shielding.
  4. The height of the stacking of different goods is tested, not only by empty channels.

3. Collisions caused by the intensive use of labels

When multiple labels respond, the reader needs to be identified in series through a collision-resistant protocol. The typical air interface of the UHF project is ISO/IEC 18000-63:2015, the corresponding number of labels, the speed of identification is influenced by label density, the reading writer parameters and on-site reflection. The project can stabilize the device under both "reduced labels" and "high labels". Over small parameters increases impact, over large parameters increases free time gaps, and cannot cover all scenes with a fixed value.

4. Miscalculation at the operational level

A tag read does not prove that the material completed a valid passage. Portal applications should account for the time window, direction, repeated reads, and the order in which adjacent antennas detect the tag. If an antenna reads the same tag continuously for two seconds, for example, software can merge those reads into one event. If the entry antenna reads it before the exit antenna does, the system can record a completed passage. Calculate time thresholds for the actual travel speed and portal length rather than adopting example values unchanged.

Set of implementable test steps

The test should not only record " readable or not " , but also " where it was read, several times, and whether it was read wrong. " It is suggested that a test form be created that would include the following items:

Recording indicators can include reading success, time-consuming single event, number of out-of-area errors, number of times the label repeats the device and number of exceptions. Test data should indicate time, material type, label type, antenna position, reader power and environmental state, to facilitate subsequent recurrence. For points that cannot be read in a stable manner, the problem of tag installation, sky cover, frequency conflict or software filtering, and then adjust parameters.

Conclusion: frequency selection is only the starting point

The core of the RFID application is not to pursue higher power or more distance, but rather to match frequency bands, labels, antennas, materials and business rules. The LF, HF for controlled close-range recognition, UHF for lot and longer-range collection, and microwave bands for a more careful assessment of the field environment. When the project goes down, it should be based on both real material and complete equipment testing, so that the anti-disruption design can be put at the system program stage, instead of waiting until it reaches the line.