RFID Asset Inventory: Choosing Tags and Setting Up Readers
RFID Knowledge

RFID Asset Inventory: Choosing Tags and Setting Up Readers

PublishedShanghai Zejie Smart Technology Co., Ltd.

Point 1: Take the inventory off first and don't rush to buy the equipment.

RFID (radio frequency recognition, in short, the technology for remote reading of label information) is the first thing to do when you take a field inventory. The type of asset, set density, metallic ratio, sources of environmental disturbance on the ground, these factors directly determine the label frequency, antenna power and dot programming. Servers that are heavily arranged within the desks and cabinets, label selection and antenna layout are two different things. We saw the customers on the project and we bought it, and it was only 60 percent of the field test recognition, and it cost more than the equipment itself.

It is suggested to start with a list of the materials (metal, plastic, wood) that are the object of an inventory, the frequency of asset movements (fixed or often moved), the accuracy requirements for an inventory (by area or by item), and whether there is any shielding or jamming source on site (e.g. electrical distribution, metal shelf-intensive areas). This is clear about what the selection of the later type is.

Point 2: Label frequency and seals are selected by scene, not as expensive as possible

The RFID label mainstream splits the UHF (UHF, working at 860-960 MHz) and HF (HF, 13.56 MHz). The high frequency is much more used in asset management, because it is read from a distance (3-8 m), and bulk recognition speeds are fast. But UHF can decline very strongly on metal surfaces, and direct posting of metal assets will not read.

Several practical selection experiences:

When Shanghai-based technology is working with manufacturing customers, metal platforms and common shelves are usually used in combination with two labels rather than one.

Point 3: Reader and antenna dots, where the recognition gap is drawn

Readers (also called readers, equipment for launching and receiving radio frequency signals) and antenna placement programmes are key to project success. There are three common approaches:

The most problematic of the regional coverage is antenna angle and power setting. An empirical value: UHF antennas in a conventional warehouse environment, with a stable radius of 4-6 metres, and a significant drop over 8 meters. Metal shelf-intensive areas need to add the number of antennas, and reduce individual antenna coverage by about 30%.

The antenna is also very specific, and it is generally the most visible to paste a label. If the length of the passage between shelves is less than 2 metres, it is recommended that both sides be equipped with antennas, so as not to have enough one-sided exposure.

Element 4: Specific regulations on the position and direction of stickers

The labels are not right, and the best equipment is not read. These are drawn from the post after stepping through the pit:

Element 5: How do you get the data to the asset desk? Don't skip the step of docking the system.

Many of the project hardware is running out, but data cannot be entered into a desk, and then it's manually recorded twice, and the count efficiency is not really improving. The RFID data is going to go into the asset management system, usually with two paths:

At the docking stage, care is taken that the EPC code for the field map - the RFID tag (a single global electronic code, a "identity number" like a label) is bound to the asset number, or it's read only about a bunch of meaningless numbers. We usually check data interface formats with clients in projects, then debug them, and the sequence is more problematic.

Point 6: Small-scale pilot, then bulk spread

Do not come up and cover the whole. First, pick a small area of 50-100 assets to pilot, run the entire process from tag paste, equipment deployment, data acquisition to system interface.

After the pilot is completed, it will be extended to the entire warehouse or floor, and the parameters of the extension (such as antenna power, tab spacing) can remain unchanged, but also need to be fine-tuned to the environmental differences in the new area. The whole project is usually reasonable for 2-3 months from start-up until steady operation.

The core of the RFID asset inventory is three things: tags are right, antennas are set, data is broken. These three steps are solid, and subsequent extensions are a copying of paste. Dismantling needs by scene, moving on by pilot, data validation, is a secure path that Shanghai-based Sieve technologies have validated in several projects, making it cheaper than to put a big investment at a time.