The resolution of the application of electronic tape tags in equipment and cable seal management
RFID Knowledge

The resolution of the application of electronic tape tags in equipment and cable seal management

PublishedShanghai Zejie Smart Technology Co., Ltd.

The core value of electronic plaster labels is to combine "physical seal" with "data identification." It embeds a RFID or NFC chip in the traditional Nyronza belt structure, which must be severed before it can be removed, and each label has an independent electronic identity that can be quickly read and written into operational information. For equipment and cable management scenes that require compliance auditing, and that want to reduce errors in manual billing, this dual structure of "physical lock + data lock" is the underlying reason why it gradually replaces lead seals and paper records.

Point 1: Find out what the electronic tape label is.

It's like a nylon with a close-up, but inside a fixed block that straddles the lead or tail, it has a chip. When it is tightened, the labels are physically bound to the encapsulated, and they have to be cut off in order to be removed, and the damage marks are visible; the device numbers written on the chip, the time of sealing, the operator, etc., can be read out by handheld terminals or fixed readers.

Compared to the traditional lead seal, the combination of plastic seals and paper table accounts, electronic bandage labels turn "Who sealed it, where sealed it, when" into a retroactive data stream. The dual structure of "physical lock + data lock" is its most valuable value for an audit of assets or for a scene that needs to be protected from internal irregularities.

Element 2: Determine which equipment and cables are suitable for electronic sealing

Not all cables need electronic seals, and the cost is on the blade.

Point 3: Keep an eye on the five parameters when choosing a model

The five parameters are almost unincorrected when they are purchased, as they are easily bypassed by sales tactics:

  1. Chip frequency. HF, 13.56 MHz, typically NFC, is short-reading/writing distance, usually a few centimetres, suitable for point-to-point confirmation; UHF, 860-960 MHz, can read/write at 3-8 metres, suitable for the warehouse mass count. Do not seek "flority" blindly, depending on the work distance.
  2. Memory Capacity. Only one ID (thousand bytes) is sufficient for retroactive account; select 1K-8K byte capacity if you want to write in the chip a record of the inspection, sign of the responsible person, etc.
  3. Read & Write Protocol. Confirms whether the chip meets international standards such as ISO 14443, ISO 15693 or EPC Class 1 Gen 2 (commonly known as ISO 18000-63), which is relevant to subsequent compatibility of reading and writing equipment with different manufacturers.
  4. Strength of the force.. The cable seal usually requires 30-80 kg of pull, with a specific view of the diameter and weight of the subject. The outside load is recommended for stainless steel bands, which can be over 100 kg.
  5. Protection level. The outdoor or wet environment suggests an IP67 and above (dustproof and short-lived water impregnated without prejudice to use) with a chip wrap that is resistant to -40°C to +85°C temperature range.

Point 4: Set the data structure and code rules to die before you go online

Many teams go online and change the code back to the end, with the result that the stock labels are all disabled. It is recommended that the following be finalized with the IT department before bulk printing:

Element 5: Embedding sweep actions into existing workflows

The tools are better, and if the workers are too busy to go around, they will be empty.

  1. When sealing. The operator, when fastened, must scan the label with a PDA (hand-held data terminal, industrially used swipe guns and tablet combination) to write to the operator and time, and the system automatically verify whether the device number matches the current worksheet.
  2. During the inspection. The inspector sweeps the label before he goes to the device, and the system is a direct popup alarm when the interval or tag is changed as compared with the last time it was sealed.
  3. When it was dismantled. The removal must be preceded by a tag-sweeping authorization, which is not to be cut until the authorization has been passed, and the instant system is recorded as destroyed and sent to the administrator for notification.

Shanghai-based Sieger Technologies, Inc., in a number of trades, usually pushes these three steps into the MES (manufacturing enforcement system) single-way nodes, turns sweeps into mandatory actions in processes, and workers cannot move on without cleaning, with minimal resistance to landing.

Point 6: Three common pits must be avoided early.

Concluding remarks

The electronic tape label is the "physical seal" that is actually being upgraded to "data seal." The key to using it is: keep an eye on the frequency band, capacity, protocol, pull, and protect five core parameters when selecting; pre-line the code rules, status fields, three pieces of offline cache pre-consolidate in the system; and then push the sweep action into MES, patrol, dismantle etc., without creating another set. If you have a thousand units of equipment or cables, and involve compliance audits or periodic inspections, from this point of departure, it would be much more smooth than the direct bidding type.