What are the ways to take stock of RFID?
Industry News

What are the ways to take stock of RFID?

PublishedShanghai Zejie Smart Technology Co., Ltd.

The RFID CDs are divided into three main types of reading devices: fixed (smart shelves, door-ban access, tunnel readers), handheld terminals, mobile robots or unmanned aircraft mounted mobile scans. The UHF frequency segment (860-960 MHz) is the mainstream selection for most of the inventory scenarios, identifying distance, and being resistant to interference and multilabelled read at the same time, clearly better than the HFC and LF sections.

What are the main ways to achieve this?

The inventory is essentially "quantity, fast and identifiable reading of electronic labels on objects". There are three main routes in hardware form.

Fixed-Stand-Step Points. On the shelf, through the channel, with a read-written and antenna at the entrance, the tags enter the area automatically and are automatically collected. Common forms include smart shelves (one set of antennas per floor), RFID secure doors (entry-trading) and RFID tunnel machines (a single-time identification of the whole box of cargo through). The advantage is that no man-operated, 24 hours to be identified, real-time access control; the disadvantage is that the retrofit works are larger and the unit price is higher.

Handheld Count. Handheld terminals (like long-formed sweepers) with RFID modules are scanned by warehouse personnel on a region-by-area basis. The advantages are flexibility, low unit price, little change in the layout of existing storage spaces; the disadvantages are reliance on manual paths and operational proficiency, and high degree of variability in recognition rates.

Mobile. Load the RFID reading and writing module to AGV, inspect robots or drones, and automatically walk-scan them on a preset path. The advantage is to reduce the number of people, which can be used in high shelf and dangerous areas; the disadvantage is that the technology for locating a single repository is not yet mature enough to be used more for large warehouse rough cleaning.

How do you pick the three bands of UHF, HF, LF? Why do you take a count of the scenes and prefer the UF?

RFID falls into three main frequency bands. LF (125–134 kHz) usually reads at under 10 cm and is used primarily for animal identification and industrial control. HF (13.56 MHz, commonly ISO 14443 and ISO 15693) reads at about 10 cm to 1 m and is widely used for books, ticketing, and NFC payments. It reads reliably but at short range and can capture only a few tags at once. ISO 28560, referenced in the tag library, is the standard for libraries and archives. UHF (860–960 MHz, generally EPC Class 1 Gen2/ISO 18000-63) reads from 1 m to more than 10 m and can capture dozens or even hundreds of tags at a time.

Inventory counting needs speed, range, and volume. UHF fits all three, so it is used in more than 90% of industry solutions for smart shelving and handheld inventory. HF suits close-range, small-batch uses such as libraries and archives or tracking individual medical devices, but cannot read full cases in bulk.

Note that China allows two UHF bands, 840-845 MHz and 920-925 MHz, under the general requirements of the 800/900 MHz Radio Frequency Identification (RFID) Equipment Management Regulations issued by the Ministry of Industry and Information Technology in 2019. When choosing equipment, make sure both readers and tags meet local frequency requirements rather than using equipment configured for bands common overseas.

How do you choose the fixed and handheld? Can we use both?

Seeing the scenes is more demanding than real-time and "flexibility."

If your storage is high (over 5 metres), you have to store it in a dense or valuable form, and you need to know what level of the shelf in real time, which is more appropriate. For example, the smart shelf at the clothing retail door, with an antenna on each shelf, shows where every piece of clothing is, in real time, usually over 99%. The electrician's compliance centre uses a channel-based reader to make a whole library that can be identified with 200 or more labels.

If the storage space changes frequently, with a limited budget, people can overwhelm the inspection, and handheld is more cost-effective. An industrial UHF handheld terminal usually costs between $3,000 and $8,000, one warehouse with a dozen units to cover the day-to-day inventory needs of a medium-sized warehouse.

The two ways in which the actual project is deployed are often the same. When doing retail stores and warehouse-based projects, Shanghai-based technology usually uses smart shelves for real time positioning, handheld terminals for monthly large inventories and temporary sampling, so that it controls the overall budget and separates "high frequency" from "low frequency full capacity".

How do you choose a RFID label to get out of the pit?

The most vulnerable point for choosing a label is "labels and environment mismatches". Several key parameters are to be targeted.

Tab FormSoft, dry sticker (inlay) suitable for paper boxes, plastic packaging; hard labels (ABS, PC material, with installed holes) suitable for metal trays, cabinets, outdoor equipment; soft anti-metal labels are placed on the metal surface, with some distance sacrificed in exchange for relativability.

Chip Model. The UHF tag mainstream chip has several series of Alien Higgs, Impinj Monza and others, which are certified by RAIN Alliance, the difference is mainly in reading-writing sensitivity, memory capacity and secure encryption features. The base amount is sufficient for general inventory counts; the type of encryption is considered when it comes to false or sensitive data.

Read/Write RangeThe same chip is marked with different antennas, and the actual distance can be 15 metres from 1 metre. The larger the antenna, the higher the unit price, the more you choose, not the more you want to pursue it.

Environmental adequacy. The metal surface reflects the UHF signal, water and liquid absorbs it, and labels close to these two media need to be specific to the anti-metallic, anti-liquid type. A normal sticker can't be read on a metal box.

Failure to recognize? Common causes and approaches

The actual project count recognition rate ranged from 90 per cent to 99.9 per cent, with the gap coming mainly from several levels.

Tab MaskIn the same direction, the labels of adjacent items interfere with each other (the industry called "crash"), and the EPC Gen2 standard has a collision-proof algorithm, but it is still missing when physical cover is severe. The way to do this is to adjust the antenna angle, lower set density, and distinguish between batch readings.

The antenna is not right.The antenna is directional, with the main petals reading far and near. The direction and angle of the antenna on the shelf needs to be calibrated in situ, not so much as to be loaded.

Environmental interferenceThe frequency transformer, Wi-Fi AP, metal shelf structures may introduce interference. The frequency band compliance equipment is less disruptive, but a spectrum test is still required when the electromagnetic environment in the field is complex.

Bad label consistency. A large number of different batch labels vary in performance or a difference in the position of the label leads to a change in read rate. It is recommended that small batch tests (not less than 200) be performed, and reading rates be recorded for three days before the batch is online.

How do we get an inventory of the WMS or ERP?

RFID Zreader is responsible for reading only the signal strength of the label ID (EPC code) and RSSI, which require mid-level translation into business events and then to be pushed to WMS or ERP in the form of interfaces.

The interface usually takes two ways: real time push (MQTT, WebSocket, Kafka etc.) and time-shift (RFTP file drops, RET API time pull). Real time pushes scenes that are suitable for smart shelves such as those requiring a millisecond response; fixed time round call is appropriate for day pallets, monthly pallete type of batch operation.

EPC encoded maps to SKU, which are recommended for integrated management in the master data system and not hard-coding in RFID intermediates. A label may flow across multiple business systems and it will be very difficult to maintain at a later stage of inconsistent coding rules.

Several issues that can easily be ignored in project selection and landing

The cost of the retrofit is not just hardware.. The laying of antennas, line-up, shielding, software docking and commissioning are often more expensive than the equipment itself and are reserved for the budget phase.

Label procurement requires loss. The entire process of labelling, transport and inventory is labeled down and routine 5 per cent-10 per cent of the goods are reserved.

The training can't be done just once.After standardization of the operating process (posting, routing, abnormal handling), at least two rounds of training are given to first-line staff and one round to supervisors and emergency response personnel.

The acceptance criteria need to be clear.. The identification rate, multiple label reading speed, interface stability indicators need to be specified in the contract and test methods, otherwise there will be much controversy after going online.

The RFID inventory is a engineering project in itself, and hardware, software, and process are working well.