What modules do RFID smart asset management contain?
RFID Knowledge

What modules do RFID smart asset management contain?

PublishedShanghai Zejie Smart Technology Co., Ltd.

The core modules of the RFID smart asset management system are usually divided into six blocks: labels and readers, capture networks, intermediates, business functions, interface integration, privileges and visualization. Any missing link is a "data-free but non-use" state -- from data starting to panel, the system can really take on the responsibility for asset management.

Element 1: Labels and readers are the starting point of the entire data chain

The labels and readers are often ignored, but they are the "geographical base" of the system. Three parameters cannot be vague when choosing a model: frequency band, storage capacity, reading/writing distance.

Frequency bands selected by asset type

Code code directly determines whether a later batch drive is possible

It is recommended that the EPA Global Gen2 or ISO/IEC 18000-63 agreements be followed in a uniform manner, each label being written into the only TED and rewritten EPC area worldwide. The code should be "one size for an asset" and leave a user area of at least 64 bytes to provide additional asset information for subsequent use. Shanghai usually helps its clients to write code codes into their master data files first, avoiding "two yards for a later merger " .

Readers and antennas match the scene.

Fixed-readers are often equipped with 4-8 antennas covering shelf passages, door closures or production lines; handheld terminals are used in bulk and temporary inventories. Read-and-write distances are not as good as they are - UHF is prone to blind areas in metal-resilient workshops, which require on-site debugging through antenna angles and power (generally 10-30dBm).

Element 2: The collection network decides whether the inventory will really save people.

The collection layer includes handheld terminals, fixed-type readers and three types of equipment with a closed antenna, each piped one.

Device Type Typical scene Read Distance Number of deployments
Handheld Terminal Warehouse bulk, field inventory 0.5-5 m 1-2 per class
Fixed Reader Garment passage, linework 3-10 meters 1–2 units per 1,000 m²
Door-free antennas Access, dangerous stores 1-3 meters 1 set per entrance

The three types of equipment are usually powered by PoE, with a web line or Wi-Fi feed back and access to the offsite branch by 4G. Delays in data return typically require control within 2 seconds, otherwise real time count is discounted.

Point 3: Intermediate to wash dirty data into usable events

Readers report the original signal, which is rereading, misreading, and missing. The middle one does three things:

The intermediate layer usually provides external access to RESTful API or MQTT interfaces for subscriptions to event streams in the business system.

Point 4: The business function module is the real user component

This layer is the most direct user-awareness module, including access to library registration, return of applications, inventory and end-of-life functions.

Registration of the library

The new asset is entered with a scan or batch reading label, the system automatically generates the asset number, and binds the phrases of name, specification, department, user, place of storage.

Access, restitution and redeployment

The employee swipes the asset, automatically records the recipient of the door-to-door antenna, time, asset number, and then brush it again once again when returned. When a cross-sectional transfer is made, the asset status changes from "in-A" to "in-B" and generates a transfer order within the system.

Stock count: Periodic and Loop Disk

The periodic disk (usually monthly or quarterly) is completed by hand-held terminals, which are then scanned on site in the warehouse, and can be cleared of a shelf label in 5-10 seconds, 10-20 times faster than traditional manual inventory. The loop drive is done by region, in groups of quality, and the load of the inventory is distributed over every day, without affecting daily operations.

End of life and depreciation

Discretion information is sent to the financial system in tandem, automatically calculating net values and depreciation eliminations to avoid long-term discrepancies.

Element 5: Is the interface integration decision system "live" in the enterprise?

The value of RFID asset management is ultimately enhanced by integration.

The interface approach recommends that priority be given to the RSTful or WebService, avoiding direct reading and writing of each other's databases. Synchronization frequency is set by scene — real-time synchronization of asset status, and depreciation data can run for approval every morning.

Point 6: Permissions, logs, visualization are three supporting modules that cannot be bypassed

Permission Levels

The system administrator (configuration, access to all logs), the departmental asset manager (management of assets in the department), and the general staff (admission, return, viewing of one's own assets) are at least three levels.

Operation Log

Every issue, return, disposal, and edit to asset information must be logged, including the operator, timestamp, IP address, original value, and new value. Retain logs for at least three years to meet audit requirements.

Visualize the viewer

The board usually shows: total assets and their distribution by classification, idleness, over-period outstanding list, depreciation progress, inventory difference. The manager opens the system to see the overall state without having to turn over the report to find a number.

The six modules are fully fledged from the data starting point to the panel, and the RFID smart asset management system is really going to be a good-to-man, good-to-man, good-to-decision tool. Selecting models suggests that business function modules be able to match processes, then capture layers and label capabilities, and finally assess integration and access -- in reverse order, easily buy back a bunch of hardware without using it.