What is an rfid electronic label: composition, coding, encapsulation and reading/writing process and description of type
The most important difference between the RFID electronic label (RFID Tag) is that it is a non-contact recognition carrier with chips and antennas, which exchanges data through radio frequency signals and readers to identify objects, trace assets or carry information. It is not optically calibrated, re-written, more remote to recognize and can be read in bulk.
What are the components of the RFID electronic label?
A label usually breaks into four pieces: chips, antennas, panels, and seals.
The only TID (worker identification), EPC (product electrocode) and user data area in the chip is labeled "brain". The antenna is usually an aluminium or copper wire that is etched on a base plate, which is used to receive radio-frequency energy from readers and to re-launch the data they store. The panel is a carrier for chips and antennas, most commonly PET, PI film. Cover layers are common options based on scene stacking, epoxy resin, ABS plastic, ceramics, designed to protect water, heat, and metals.
The common phenomenon at the industrial scene is that: a direct paper label on a metal shelf, which falls from two metres in theory to almost impossible reading; and when you switch to a metallic-resistant suction seal, it's basically back to normal -- this is the most visual effect of the seal on performance.
How did the RFID tags come up? What's the point?
RFID encoding is more than storing a string of numbers. EPCglobal's Electronic Product Code is widely used and comes in formats such as EPC-64, EPC-96, and EPC-256. EPC-96 is widely deployed and can accommodate about 26.8 quadrillion distinct codes (2^96). Chip memory generally has four banks: reserved memory for access and kill passwords, EPC, a factory-set unique and immutable TID, and user memory for application data.
Writing is in two ways: TID and the initial EPC are recorded by the manufacturer; then the user reads and writes on demand. Early one-time writing labels (WORM) are still available, but most new projects are supported with multiple reading and writing tags.
Why would the RFID label be sealed? What are the common forms of the envelope?
The seal directly determines the environment in which the label can be used. The same chip + antenna, with different envelopes, varies greatly between reliability, reading distance and lifetime.
- Paper non-dry glue label:Printed face + RFID is a low-cost patch, mainly for express delivery sheets and retail packaging.
- Note plastic shell label:ABS or PC material is sealed, waterproof against chemical corrosion and commonly used in industrial parts, pallets, revolving containers.
- Ceramic label:High temperature tolerance can be up to 200°C, often in car coating lines and metal thermal workshops.
- Soft anti-metal labels:The internal suction material or the iron oxygen layer, which is specially attached to the metal surface, restores the reading distance from a single-digit centimetre to the conventional range.
How did the RFID tag read and write?
A complete RFID interaction usually takes four steps:
- Readers continue to send radio frequency signals at specified frequencies. Common work bands are LF (125-134 kHz), HF (13.56 MHz), UHF (860-960 MHz), microwave (2.45 GHz) fourth tranche.
- When the label enters the radio frequency field, the coil is exposed to currents and activates the internal chip.
- The chip will re-disperse the stored data by "reverse disspersion" -- using the chip to change the antenna reflection and to adjust the data to reflect the wave.
- Reader decodes the signal and sends the data to the upper-level systems such as MES, WMS, ERP.
The whole process is usually done in tens of milliseconds. When multiple labels are present, the reader starts a collision-proof algorithm (e.g. ALOHA or tree-shaped algorithm) to cross-examine each and avoid data conflicts.
What are the main types of RFID labels?
There are two categories of energy source:
- Passive Tag:The label itself is free of batteries, and the radio frequency field that is powered by a reader. It is low cost, small size, long life (more than 10 years in conventional environments), which is the main force for logistics and retail scenes.
- Active Tag:Self-contained buttons or lithium batteries, active broadcasting signals with reading distances usually ranging from a few to several dozen metres, are often used for vehicle identification, large container tracking and personnel positioning.
Four categories by frequency:
- LF (low frequency 125-134 kHz):It's very penetrating, typical distance 5-10 cm, animal earmarks, door-barlocked Cardo.
- HF (HF 13.56 MHz):Around 10 cm, NFC payments, library management, and medicines are used retroactively.
- UHF (UHF 860-960 MHz):Reading distance 1-10 m is a frequency where storage, retailing and logistics are deployed more widely.
- Microwave (2.45 GHz):Distance but directional, mainly for ETC road charges.
When shanghai-Shanghai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Tai-Wai, you usually advise customers on the selection of a project in practice, you will determine the frequency by identifying distance, environmental characteristics and three dimensions of the object to be attached, then fix the form of sealing, and finally pick the chip type and antenna gain.
What parameters should be the focus of the selection?
- Read distance:The specifications generally indicate the limit value in air.
- Frequency-band compliance:The UHF allows for different frequency bands in various countries, such as North America 902-928 MHz, Europe 865-868 MHz, China 920-925 MHz, to confirm when the goods are shipped abroad.
- Storage capacity:EPC sector at least 96 bit; user area varies from 512 bit to several Kbit, selected on an as-needed basis.
- Environmental sustainability:IP level, work temperature range, anti-metal demand.
- Compatibility of the agreement:The UHF General Agreement is ISO/IEC 18000-63 (i.e., EPC Class 1 Gen 2), which is good for inter-plant compatibility, and gives priority to this category.
Ultimately, the RFID label is a triad of "chip+ antenna+encapsure" with core values that attach identity information and data to the object so that people and systems can read it without contact.
It is recommended that you clear three binding columns before you do so — identifying distance, environmental characteristics, adhesion — then re-enacting from the frequency and then taking a sample to take a live reading range, which basically sifts out most of the inappropriate products.

Ms. Lei