How do you select UHF electronic tags for rfid: read distance, protocol match scene
Learning distance is the result, not the parameter.
The first reaction of many people to the UHF electronic label is to look at the distance from the parameter table, and think as far as possible. It's really a frequency, antenna, environment, three variables that are superimposed, not a fixed parameter. The core idea for this selection is to see the scene, then agree on an agreement, and then use the actual data to extrapolate the reading distance.
First, frequency. The UHF RFID bands set by China are 840-845 MHz and 920-925 MHz (defined by the Ministry of Industry and Communications ' related radio regulations), with a marked difference in the performance of the same label under different frequency bands, which is usually slightly more distant than 920-925 MHz.
Also, the antenna. The linear polarized antenna is far away from being read but sensitive to the labels, with a slightly shorter polar antenna reading distance and tolerance of the labels being placed at any angle.
The metal reflects the signal, so the labels are not read, and water absorbs the signals, and the reading distance shrinks. We have done an inventory of garment factories, where normal paper labels can be read up to 8 metres in a cloth warehouse, then they can be reduced directly to 3 metres in a washing shop with high water content, and then replaced by anti-liquid labels.
General range of reference reading distance: Non-sourced general labels are 1-10 m in an open environment, anti-metal labels 3-8 m and battery active labels can be as far as 20-100 m but have completely different cost structures.
The protocol is not as new as possible. Matching the reader and back end is all that matters.
The protocol determines how labels and readers "dialogue" are written in the back-end system. Currently, the mainstream is ISO/IEC 18000-6C, commonly known as EPC1G2 (e.g. EPC Class 1 General 2 - Common to 6C) with most newly released readers and labels being compatible with it and prioritized when choosing a type.
The other agreements are applicable in each of the following contexts:
- ISO/IEC 18000-6B: Early agreement, slow reading but stable writing, and some old industrial lines are still in use.
- GB/T 29768: Chinese military materiel RFID standards, extended on the basis of 6C agreements, generally inaccessible to private enterprises.
- ISO/IEC 18000-63: Almost identical to 6C, except that the document number is different and a name difference is not addressed in the selection.
The real easy to step on is the details of the protocol. It also has a "6C compatible" label, which supports only the EPC area (usually 96-128 places), or even greater memory; some are old and some support new security features. Before there are readers, the reader's version and the tag data manual are looked at more than the vendor's verbal commitment.
The scenes determine the direction of the selection, and four typical scenarios are based on actual experience.
Warehousing logistics
The typical application for mass reading and distance is the whole tray access library. Readers are placed on a dragon door or forklift, which requires identification of dozens of labels at a time. This scenario gives preference to either an ordinary paper-free tape label or ABS label (a common hard plastic shell label), a Circumpolar antenna, with 6C in the protocol, without having to pursue anti-metals.
Retail stores
The general labels are not readable by the cosmetics that are packed in metal, either soft-resistant metal tags or specially designed RFID caps. The mass count requires low reading and we prefer to use labels that support the User area, store the commodity information in two layers, and add a new count speed.
Asset management
Most of the equipment is metal casings, in small quantities but requires precise positioning. Such scenarios are typically resistant to metal labels with small sizes of ceramic or PCB materials, and are placed in a shell dent or fixed by screws. The agreement also selects 6C, which is key to the size and type of labels that are linked to the asset billing system, otherwise the tags and data are not matched to numbers and are white.
Production line retroactive
High temperature, friction, and chemical cleaning are normal and common labels cannot hold.
Three common selection error areas
Read only nominal reading spacing, ignoring actual environment
Tag datasheet read ranges are generally measured in open laboratory conditions. In real warehouses, workshops, and stores, expect about 50%–70% of that range.
Buy all the labels for money.
Price-priced labels usually solve a particular problem (metal resistance, liquid resistance, heat resistance), and it is wasteful to spend high prices on scenes where these capabilities are not required.
Ignore compatibility tests for rewrite firmware and labels
The 6C labels of different manufacturers may vary in their status font, password mechanism, and are prepared in bulk without small batch tests, with the cost of returning to work far exceeding the price difference per se of the label.
Recommendations for the exercise
The three steps of the selection are much lower than the probability of persecute.
First, the scene is clear and needs for reading distance, interference resistance, protocols, unit prices are prioritized, and no attempt is made to solve all problems with a single label.
Step two, small-volume measurements. Each scene selects two or three brand labels, which are read on the actual object by a live reader, and records the drop rate and repetition rates within one week, with data compared to the parameter table.
Step three, confirm protocol details. Reader's solidware version, Label Data Manual, back-end system interface protocol three-way alignment and reordering.
Shanghai-based technology typically recommends that bulk purchases be made in the same direction as both anti-metal labels and generic non-dry glue tags. This process, although taking several days, avoids lateral re-engineering of hundreds of thousands of labels.

Ms. Lei
Mr. Pang