How the RFID storage logistics system is deployed: Elements of implementation for the design and tracking of logistics nodes
The deployment of the RFID storage logistics system should be in order "first node, then equipment": First, we list the goods from the car to the next logistics node, and then we answer each one, "What is read here, when, what does read, what can not read," and then reverse the reader, antenna, label and middle. The device parameters are better adjusted, if node logic is not clear, then there is a leak after the line, and the serial reading and data are not kept to account. This paper gives the details that are easily ignored by the order of implementation on the ground.
I. Prior to going on RFID, it's not worth the price.
The common term is "SKU over 500, and the daily access to a hundred or more of the warehouses is appropriate for up to RFID," which is a reference criterion, but it is more accurate to judge on three questions:
- How many do you need to identify for a single job?Dozens of boxes in a tray need to be counted once before the bulk reading advantage of RFID can be realized; if most of the work is one piece of pick, bar code scanning is not inefficient.
- How many deliveries are there?The more people the RFID saves from the stocking and reconciliation of vehicles, vehicles to the transhipment site, and trans-shipment sites to the client, each time they are handed over, the more it is possible that the RFID will save.
- Do you have a recycled load?Assets such as swing boxes, pallets and cages are labelled at a time, used repeatedly, the label costs are the lowest to be distributed and often the entry point with the fastest return on investment.
Two of the three questions are positive, and it is worth assessing the RFID program. Conversely, a warehouse with small links, which is mostly silo-scaved, tends to be more cost-effective with bar codes plus PDAs.
II. Nodal table: answers to five questions per reading point
The most valuable thing before you do is to get the goods out of the picture, and then make a table of each node on the chart. Each node has to answer five questions: what data is read, what actions trigger reading, what business systems do after, what remedial processes are not read, who finds it wrong.
| Nodes | Collect content | Recommended Device | Read Trigger | Remediation when you can't read |
|---|---|---|---|---|
| Receiving platform | Tray ID, number of arrival boxes | Door Fixed Reader | Ground or photovoltaic forklift passing | Handheld catch-up, manual confirmation of discrepancies |
| Incoming and accepted | SKU, batch, quantity | Readers or handhelds on the receiver | The operator scans the manifest and starts reading. | Check the box. |
| Up! | Tray and Repository Tie | Forklift-mounted readers, space tags | Forklift forkdown. | Handheld machine to clear the storage space and tray |
| Selection and review | Pick out the box number and match it to the order. | Review of the desk reader or tunnel machine | The swing space is on the review desk. | Line-by-code review |
| Load the door. | Loading, license plate, direction. | reader-O-Z-O-R-O-R-T-E. | Vehicle on signal and forklift passing | The car is locked up, the handheld is back on the line. |
| On the way. | On the list of cars | Car Reader | Door-knit incident | Full-volume match on arrival. |
| Sign and receive | The box number, the signer. | Handheld Reader | The recipient confirmed the receipt and receipt. | Confirmed by box by discrepancy list |
This chart is finished, and it becomes clear which nodes have to be fixed, which are filled with handhelds, and which are the only ones that will become clear. One of the three logistics projects we've done is to compress the number of readers from 32 to 19 as originally planned, with the budget saved on upgrading the equipment at two key nodes: the loading gate and the receiving platform.
The node chart also serves as the basis for the subsequent acceptance test. If it is not written, the "not read" at each node indicates that the process of this node has not been designed and should not be used for construction.
III. ENDING THE HOSPITAL DOOR: THE COVERY IS THAT I CAN'T GET A READING LATER
The door-reading point is the most popular place to return to work in the project. Many people think it's hard to read everything, and the real problem on the ground is not to read much. The inside of the platform is usually a temporary storage area for the garage, with only two or three metres from the door for the goods to be loaded, and the reading machine continues to read them, and the system misjudges that they are already out of the library. If this type of reading problem is not compromised at the debug phase, then it is difficult to fix it when you go online. Control links can start in five ways:
- Read with an external signal.reader does not drive frequently, access the optical switch or geosensor circle through GPI interface, and forklift enters the door area before reading starts and stops after leaving. This one is done, and serial reading problems solve most of the problem.
- Power is set on demand.A standard warehouse doorway is 2-4 m wide. A single reader with four opposing antennas, mounted on both sides, generally needs only 1-2 W ERP (effective radiated power). Turning the power up doesn't improve reliability inside the portal. It can instead capture tags at adjacent doors and staging areas.
- Sets a RSSI threshold filter.The intermediate receives only reading records with a signal strength above the threshold. The threshold is not filled by experience, but is determined by the actual RSSI distribution in the gate and temporary storage areas.
- Physical isolation.The temporary storage area is maintained at a distance of more than 3 metres between the gate and the adjacent moon door is more stable than simple modulation of software parameters by adding metal partitions or suction material to the adjacent platform.
- The judgement is in the direction.The programme of placing the antenna on one side alone does not distinguish between “move out” and “ move back to the door”.
Antenna polarization suggests a one-and-a-one-way rotation, or a direct selection of the circle polarized antenna, and write into the construction specifications to avoid missing side-set labels. Also, the reader’s Gen2 session parameters are set by scene: A fast-passing scenario with a door-ban channel, which is suitable for flipping the A/B double target with a S1 or S2 session, so that the same label can be read multiple times during adoption; The static CD is used for S2 or S3 sessions to reduce the number of read-up tabs and leave the reading opportunities to unread labels. When multiple readers are close, you need to open a intensive reader mode (DRM) to avoid interference.
Under the Ministry of Industry and Information Technology's 2024 Regulations on Radio Management of RFID Equipment in the 900 MHz Band, UHF RFID equipment in China uses 920–925 MHz. The rules took effect on November 1, 2024. Equipment approved at 840–845 MHz under the old rules can remain in service until retirement. Verify that newly purchased readers have type approval for the applicable band, and choose tags tuned to the same frequencies.
IV. TRANSPORT RESPONSIBILITY: DEFINITIONS QUITED A VIEW
The reading point on the delivery line is calculated first of all how long the labels are in the readable area. For example, the direction along the readable area is 0.8 metres, with a linear speed of 1.2 metres per second, and the single box is only around 0.67 seconds in the readable area. If there is a single label within each box, complete reading in 0.67 seconds, read and write, the session settings and number of antennas are to be matched by this time.
The distance from the antenna to the label plane is usually 30 to 60 cm. Too far-power is lost, and too close the label is easy to read blind through the right below the antenna. Reads high-demand scenarios at box level or single grade, suggesting using a tunnel reader with a shielded barrier that increases both reading rates and interference on both sides of the line.
The more problematic thing on the delivery line is "where do you read the labels?" It's too long to go in a box, and the previous one can be read only when the last one enters the reading area, resulting in data confiding. The solution is to install a light switch around the reading area, which is divided by a time window between two light telecommunications signals, while requiring that the transmission line ensures a minimum box spacing. Each route of the split node is separated by an antenna, otherwise the two flowing labels cannot be distinguished from the source after they are read in the same antenna.
V. Label selection, paste specifications and coding rules
The label is selected by the object, not as expensive as it is:
| Attach Object | Recommended Tags | Attention |
|---|---|---|
| Box box overpack | Non-dry glue tags (inlay, i.e. unencapable group of chips with antenna) | Minimum cost. Avoid metal and liquids in boxes. |
| Plastics swingbox, tray | Note plastic or hard-cover labels | Impact-resistant, clean, recycleable |
| Metal shelf, metal pieces | Anti-metallic labels with suction layers | It's not like normal inlay can read on the metal surface. |
| Drum-filled liquids, cold-chain cargo | Anti-liquid labels or additional containment layers | Put it on the edge of the barrel, avoid the liquid-faced center. |
Paste position to be written into the operation SOP (standard operating procedure): The height of the same product must be consistent and distanced from the metal or liquid in the case. Liquids are severely decaying with UHF signals, a full barrel of liquids is labelled as normal, and read distance can drop from 3 m to less than half m. We have encountered this in a cold chain project, which is closer to the edge of the barrel, and after avoiding the liquid surface, the reading rate has returned from 70% to more than 96%.
The code rules are to be finalized at the beginning of the project, and one of them is often confused:The asset code of the tray itself and the logistics module code for this consignment on the tray are different.Recycleable trays, swingboxes, should be labelled with a GRAI (Recoverable Asset Mark) to manage the asset itself; the logistics unit formed after a ticket grouping, marked by SSSCC (series of freighter box codes), changes each shipment; individual goods are used as SCTIN (Sequenced Global Trade Project Code). If the tray asset label is used directly as SCCC, the second transfer of the tray is mixed with the record of the last ticket.
Encoding length, prefix, whether or not to keep an extended field is written into the code instruction. The label is written and recommends locking the EPC area and setting access passwords to prevent error in writing; for items that are required to protect against forgery, the only TID from the plant can be registered with the system. Early uncertainty regulation, each time a new supplier is accessed at a later stage, is done with data cleansing.
VI. Tracking in transit: fixed, vehicle-mounted, handheld three tiers of cooperation
The only way to track a fixed reader in a warehouse is through a fixed-reader, which requires three layers of equipment: a fixed cover of the warehouse entrance and exit and the tram door frame; a load-up in the transport compartment for post-loading inventory and en route change monitoring; handheld as a mobile patch point, processing abnormal items, temporary count and sign-off confirmation. The mainstream handheld has a distance of 3-8 metres, and the national production machine has stabilized support for mass readings of more than 100 per second.
The actual effects of the car-mounted readers, often and programme descriptions, are different for three main reasons:
- The labels in the deep of the stack cannot be read.The box signal, which is packed in the middle, is blocked by the goods that are around it.
- Periodic scanning is prone to misstatement.If the scan is done every 5 to 15 minutes and “not read this time”, the police will be called, the driver and movement control will soon be misreported and the alarm will not be observed.
- Vibration and power supply.The vehicle-borne environment is highly vibrated and voltage is volatile, with the selection of a graded equipment and the fixed and waterproofing of cable connections.
The more conservative approach is to use the box number read at the front of the car as a benchmark for “in-the-car list”; to change the scan from an en route to a door-opening event, which is triggered by a door-opening event, with magnetic and electronic locks on the doors open, without requiring case-by-box confirmation; to use the two conditions of “continuous multiple unreading” plus “time open-door records” in determining loss before calling the police. Upon arrival, the full volume matching of the offload points is used as the basis for final determination. This way the role of the vehicle-mounted ZreaderZ becomes “obtainable in real time to every box” from “discovery differences after the abnormal opening”, which would be much lower.
VII. INTERLIGHTING BORDER WITH WMS, TMS
The middle is between the reader and the business system, which is responsible for making the original reading record a direct event in the operating system. The general three-tiered process: the primary reading layer records every time; the filter layer is heavy, the RSSI filters and time windows are split; the event layer output business events such as "A tray goes out of the door at a certain moment" is then forwarded to WMS (storey management) or TMS (transport management system). When this layer is thin, the downstream system has to handle its own double reading and string reading, and performance and accuracy will be affected.
The principle of the boundary is that the middle is only: "What do you read, what time, at what point?" The operational system decides "what happens after reading." For example, when entering a library, the middle is pushing the tray ID and reading time, whereby WMS generates up-to-date tasks and allocates the vault. If the middle crosses to distribute the warehouse, WMS loses control over the stock structure, which is not clear from the beginning, and changes are made on both sides of the later period.
There are three points to be agreed in advance on the design of the interface: event is to be carried with a unique ID, business system is to be hit by ID and no double-counting is to be made when reissues are to be made; the edge is to be able to cache events when the network is disrupted, and then reconnect them in order; all readers are to synchronize to NTP (Network Time Protocol) servers in a single sync, otherwise there will be errors in cross-node comparison.
VIII. HOW TO DO THE RECEIVATION AND ACCOUNTS
Many projects are accepted and read only “on-site demonstrations”, which is not enough. It is suggested that the test be quantified by nodal table:
- Based on real operating conditions.Use real goods, real stacking methods and normal operating speeds, not in case of a stowed sample box.
- There's enough samples.At least hundreds of tests were performed at each fixed reading point to blend into hard-to-read goods such as metal, liquids and so forth.
- Both indicators are counted.The drop-out rate (which should read but not read) and the over-reading rate (which should not read, but is read), are counted separately and are often ignored as a direct manifestation of the question of serial reading.
- Tray and box levels are separately targeted.Tray labels are fixed and few in cover, and can be set very high; box-level labels are heavily influenced by stacking, with realistic targets and clear remedial processes when not achieved.
- Do a peak pressure test.Many of the units work simultaneously during simulated peak hours, while multiple readers work at the same time to check interference and delay in processing intermediates.
The field debugging and pressure testing is set aside for at least two weeks. Problems identified in the test are revised back to the node table, rather than being patched only on the equipment parameters.
IX. The focus of the operational work after the line
The first is that the electromagnetic environment changes. Adding metal shelves, devices or metal door curtains changes the calibrated frequency field, and many of the blind areas are built after the warehouse has been modified. The antenna position and number are set at two to thirty percent, and the reading points are regularly checked with test labels.
The second is the mass of the label batch. The sensitivity of the labels may vary from batch to batch, and it is much less important to check the distance when a new batch arrives, than to find out why it was not read.
The third is the division of RFID and bar code. RFID is good at lot, non-contact, remote reading, unscrew, single-size fine work that still fits bar code. The two are split between the one-size operation and the other, which is hard to hand over to RFID, often with a high level of input and poor results.
Common problems
Q: How many antennas do the gates need for a month?
Answer: For a standard warehouse door 2–4 meters wide, a four-channel reader with four antennas facing across from both sides is a reliable setup. To determine direction of travel, use one group inside and one outside, adding antennas accordingly.
Q: Can RFID completely replace the warehouse count?
Response: The inventory load can be significantly reduced but not entirely replaced. RFID reads labels, which are not consistent with system data and physical objects when the tags fall off, damage or separate from the target, and still require periodic check-ups on a diskette.
Q: Does the existing WMS need to be adapted?
Response: There is usually a need to increase the event reception interface and the process of unusual handling, depending on whether WMS supports the event-driven process. It is suggested that WMS suppliers be involved in border discussions at the programme stage.
Summary
The deployment sequence of the RFID storage logistics system is: first to determine whether it's appropriate, then draw a node chart, then select hardware, integrate and eventually use quantitative measurements. As Shanghai has seen in previous projects, most of the items that have returned to work are designed by skipping nodes, starting directly with the equipment selected. The technology itself is not complex, but it is essential to align the three things that matter: the hardware performance and the business systems, so that RFID can really be a reliable source of data in the warehouse.

Ms. Lei
Mr. Pang