RFID identifies the manner of implementation in asset management and warehousing counts
The conclusion goes first: how's the RFID running?
RFID identifies whether real landfall can be done in asset management and storage ZZZZQQZZ, core is not in the equipment class, while three layers of things can fit the material and the environment where the object is being used -- label characteristics are matched to the object, reading and writing devices are configured to match the physical space structure, intermediates and business systems actually translate the data collected into operational action. Any misdirection, recognition rate, drop rate, and ability to resist interference is problematic. Shanghai has repeatedly verified this in a number of industries' RFID projects, and below is a presentation of the specific practices of each link and the pits that have been stepped on.
Label selection: Follow the material and environment of the label
Many people start off with a type of label, which is the first level. RFID divides the main low frequency (approximately 125 kHz), HF (13.56 MHz), UHF (860-960 MHz) three-stage; and passive (ion-magnetic wave power by reader) and active (self-carried battery) by whether or not to carry a battery.
The most commonly used in asset management and warehouse counts is the passive UHF label, which can be used at a unit cost of a lot of money, with reading distances usually between 1-8 metres, and hundreds of tags that can be read at one time at the same time, which are the main force of the inventory scene. But the UHF has a congenital weakness: metal surfaces reflect electromagnetic waves, liquids absorb electromagnetic waves, so labels are placed directly in metal cabinets, metal trays or more watered surfaces, and reading distance is significantly reduced or not read. In this case, a special anti-metallic label is replaced or a layer of disks is attached to the label and the metal surface.
If assets are distributed on multiple floors or outdoors, and need to be read at tens of metres or even hundreds of metres, then you have to label them, which is a 2-5 year extension for batteries, with costs ranging from several dozen to several hundred dollars. Which, in the final analysis, is the material of the object, reading distance, lot size and budget, not to go up high.
Deployment of readers and antennas: location determination data quality
Readers and antennas are located, used, and placed, directly determining the recognition rate and the rate of failure.
- Fixed door or channelA set of antennas is installed at the warehouse entrance and exit, in the workshop corridor, where items are automatically identified as they pass through and suitable for automatic registration in the access garage.
- Handheld TerminalThe inventory officer took the PDA and scrutinised it in front of the shelf for stock review, spot-checking and search.
- Forklift or delivery line vehicleReader(s) on either side of the forklift or the delivery line, suitable for mass moving counts in the warehouse.
The same labels, reading rates when they are in the same direction as the antennas polarize, are high; the deviation is negative, and the rate of missing reading increases. We have a typical situation in a metal shelf warehouse: labels on the side of a box, but on the side of the metal shelf, it's almost impossible to read from the front of the channel, then instead of changing the label to the paper surface outside the box, and moving the polarized direction parallel to the long-stated label, so we can stabilize the recognition rate.
The principle is to take an on-site survey, which will be based on the spacing of the shelf, the width of the channel, the size of the tray, and determine the number of readers and antennas.
Intermediate layer: making hardware data key to operational data
Many projects buy readers and labels, but they get online and find data that cannot reach ERP or WMS, and the problem is often at the middle level. The RFID reader throws out the EPC code, the RSSI signal strength, reading time stamping these raw data, which business system needs "which asset, who was counted at what time, whether it's normal" and the middle part of the business field, which is responsible for this conversion.
A qualified RFID medium has at least a few things to do: filter over and over again (the same label is read by multiple readers only once), merge split events, link business documents, do an anomaly alert (e.g. read assets that should not be in the area). If the middle is thin, data is inserted directly into the system, the operator sees just a bunch of unreading codes, and the RFID project becomes a setup.
Asset management and warehousing inventory counts: differences in implementation between two scenarios
Although all are called RFID inventories, the implementation of asset management (IT equipment, production tools, instrumentation instruments, etc.) and warehousing management (materials, semi-finished products, finished products) varies considerably.
Asset management is characterized by high individual value, relatively fixed quantity, and requires a back-to-back life cycle. This type of scene usually uses the combination of "passive labels + periodic handheld discs" where each asset is labelled with an anti-metallic or flexible tag, changes in asset position are automatically recorded through the entry/entry reader, and the entire floor is taken over the regular count using PDA. The focus is on ensuring that the label remains undiscovered throughout the life cycle, is not blocked, and that when data are written, the asset number is strictly tied.
The warehouse count is characterized by large volumes, high mobility, complex batch and life-cycle management. This type of scene is more suitable for a combination of "passway reading and writing + forklifts on board + line tunnel", auto-checking the entrance and exit garage through the corridor, and scanned within the warehouse from the vehicle-mounted terminal cycle. Focus is on the balance of speed and accuracy of read, and the UHF channel reader in industry currently reads hundreds of boxes of goods in one-way traffic, with a drop rate control below 1 per cent being considered stable.
A few common pits, the most frequent of them coming down from the rediscovery.
- It is recommended that suppliers with a strong and stable reputation be selected, and that the consistency test be conducted in batches if necessary.
- Ignores the field electromagnetic environment. The frequency transformer, the power-power generator, and the dense Wi-Fi base station could interfere with the UHF reading and writing, preferably by doing a spectrum survey before it is implemented.
- The RFID project is treated as a pure IT project, without involving first-line warehouse or asset managers in the process design.
- The long-term reliability of the label is not considered. Some glues are ineffective in high temperatures, low temperatures or oil pollution, and de-labelling and subsidizing increases costs and affects data continuity.
End
RFID recognizes that, essentially, the three things of "the character of the object - the environment - business processes" are clearly identified and matched with technology, and equipment selection is a result, not a starting point. If you start to contact RFID, you can run a closed loop in a small range of scenes -- select one of the assets or a library insider line, put labels, readers, intermediates, all the business systems running smoothly, and then expand on the real data.

Ms. Lei