RFID Common problems of reading electronic labels: weak signals, unidentifiable how to solve them?
Weak signals usually result from environmental interference, incorrect equipment settings, or a poor match between tag and application. There are three ways to address it. One is to reduce environmental interference. If metal or liquids are nearby, reposition the tag, for example away from a metal button to a flat area of fabric, or use a tag designed for metal or liquid interference, such as a UHF tag with a magnetic shielding layer. In dense environments such as warehouses, do not stack tags and keep at least 5 cm between them to limit interference.
Second, optimize equipment parameters, the reader's power of launch can be adjusted to recognize distance (high frequency tag power to 0.5-1W, UHF to 1-3W) and calibrate antenna angles to ensure that the antenna is reading the label area (angels are not more than 15°; if handheld readers are used, the high-value antenna (gain > = 6dBi) may be replaced by an enhanced signal reception capability, which will increase the signal strength by 30% or more. Also, the labels are matched to the reader frequency (e.g., HF tags for 13.56 MHz readers) and the frequency incompatibility is avoided as a sign decay.
II. Unidentifiable issues: from labels, equipment and processes
Could not identify the labels that need to be systematically checked, equipment and operating processes. First, check the label validity, check if the tags are written to data (a blank tag that is not identified) with a special detection device, or if the data is lost; check if the labels are damaged (e.g. chip welding off, antenna break), such failures require the tabs to be replaced directly, and it is recommended that they be kept in daily storage to avoid pressing the labels and prevent physical damage.
Second, inspect the equipment. Check that the reader is powered normally (voltage fluctuation should stay within ±5%) and that antenna connections are secure (reconnect and tighten them if needed). Restart the device or restore factory settings if it reports an error. For fixed readers, clean the antenna surface periodically by wiping dust away with a dry cloth to prevent dirt from affecting reception. Third, standardize operating procedures. Keep tags within read range (up to 1 m for HF and up to 10 m for UHF) and remove obstructions during reading. For batch reads, keep tag speed at or below 0.5 m/s to prevent missed reads. On a garment sorting line, for example, adjusting conveyor speed can improve the read rate.

Ms. Lei
Mr. Pang