Technical rfid label reliability under harsh conditions requires a decomposition statement
RFID Knowledge

Technical rfid label reliability under harsh conditions requires a decomposition statement

PublishedShanghai Zejie Smart Technology Co., Ltd.

The reliability of the technical RFID labels in a harsh condition depends on three things: the strength of the chip to connect to the antenna, the tolerance range of the sealed material, and the overall level of protection. Read-and-read distance is not significant. The real test is whether the labels are stablely identified under complex stress such as high temperature, metal, acid, vibration etc.

What are the poor industrial- and commercial-level labels?

The biggest difference between the two is long-term stability, not reading and writing distance. The same label can be used for three or five years on office equipment, but it can be placed in a car welding workshop, an outdoor electric tower, a cold storage or open-air building material dump, which can fail to read or even completely fail in months. Commercial labels seek low cost, read and write; industrial labels seek to maintain data integrity and communication stability with combined stress from temperature, humidity, chemistry, mechanical, electromagnetic, etc.

We have seen this comparison in the project at Shanghai-based Shang Jijie Tech Ltd.: the labels of the same specifications, which are more stable in a temperature-receiving warehouse near the 85°C paint house, will drop by more than half the reading distance.

Where are the most vulnerable places for RFID labels in harsh conditions?

In engineering practice, the failure is concentrated in these areas:

How much is the level of protection enough?

The level of protection is directly related to the scene and it is recommended that it be matched according to the following criteria:

When machines crash in many places, it depends on IK grade, and IK08 is recommended. The protection level can be understood as the outer layer, and the reliability of the internal chips and antennas of the label is dependent on the containment process and material, which is not enough for light to see.

What are the metal and liquid environments going to do?

Metal environment: Metal reflects electromagnetic waves and makes standard UHF tags nearly unreadable. Industrial on-metal tags typically use one of three approaches: a high-permeability absorbing layer underneath to isolate reflections, a specially polarized antenna that couples with the metal, or a metal backing plate or ceramic housing.

Liquid environment: Water absorbs microwave energy. Bottled water, biological samples of liquid objects are more suitable for the selection of HF frequency bands (13.56 MHz), but penetration in liquids is better than that of the UHF.

How much does temperature limit affect the RFID label?

The working temperature of an industrial label usually covers -40°C to +85°C, which is the common baseline for car-grade and work control.

The condensation limit of the chip itself is typically between +125°C and +150°C. Beyond this temperature range, EEPROM is error-stricken and directly damagees the chip in serious cases.

How do you verify the reliability of the technical RFID label?

Common authentication dimensions include:

What are the key parameters that should be focused on when selecting a model?

In order of importance, it is recommended that attention be given to:

If the project requires higher reliability, it is recommended that these parameters be measured over and over again at the sample stage to determine the volume option.

The reliability of the technical RFID label is not a single-point indicator, but a combination of materials, seals, processes, tests. It is suggested that small batch measurements be synchronized at the selection stage, so as to make the outer shell resistant, temperature cycles, and read and write stability in several dimensions, and then use these data to determine subsequent batching options, much more stable than looking at specifications alone.