Explore the application of RFID in grid asset security management
Currently, the EMS is being used by grid enterprises to conduct outcome indicator evaluations. The system draws data mainly from PMS and SAP systems, but lacks information on physical data in situ, while physical identification is collected through RFID intermediates and on-site collection devices, which feed back physical information in a timely manner through interface into the AMA decision-making system, achieve true accounts, cards, and items consistent vertical closed loops, and provide more accurate asset operational status data for asset security management.
1 Collection Device Selection
The application of RFID to grid asset tracking management will allow for the use of handheld capture terminals (HDIs) for information gathering on physical markings on site, and because of their operation in an electromagnetic field environment, it is necessary to consider the anti-disruptiveness of end equipment, reading and writing distance, stability, reliability etc.
(1) Anti-disruptive factor. The electrical transformer is operating in an environment that produces a work frequency field and a work frequency magnetic field, where the work frequency magnetic field interference is low frequency sensor-based. Since the signal inside the handheld terminal does not use the earth as a reflow path, the electromagnetic protection design of the handheld terminal selection is considered for the handheld terminal design.
(2) Read-and-write distance. The physical marking of the grid is usually installed on a flat-train train that is located on the base of the equipment, and at certain altitude from the ground, so that operators can read and write data easily. Therefore, hand-held reading-and-writing distances are important to reduce the distance of asset inspectors, reduce their work intensity and increase the efficiency of the inspections.
(3) The handheld equipment is re-carrying. The substations above 220 kV are large in area, larger in equipment and long in duration of marking implementation, so that the handheld device batteries must have a longer re-defunct capacity and automatically save data after the power has been lost to ensure that staff members do not have concerns about their work on the site.
2 Physical marking performance
The RFID physical identifiers, which have the advantages of waterproofing, magnetic resistance, high temperature tolerance, long life expectancy, large distance reading, encryption of data, large amount of data storage, and modification of information storage, are widely applied to network asset tracking. Therefore, ISO18000-6B metal marking is used for asset tracking management. In outdoor and hot environments, electrical devices need to take due account of ultraviolet in design and material selection, reading-and-writing distances, multiple-mark reading, etc.
(1) Reading and writing distance. In the UHF electromagnetic environment of a power station, metal surfaces shield electromagnetic waves, which significantly deteriorate when the antenna inside signs is near the metal surface. After field application, markings are applied to the surface of a flat-wire train, signal failure is significant, reading and writing distances are reduced by 50% to 70%, so that the issue of reading and writing distance is taken into account in the design of the marking shell, the containment and the marking posting material.
(2) Anti-UV. Currently, UHF passive electronic sealing casings are commonly used as ABS material, and for the return of installed markings, electronic markings are long-lived in the wind of a power station and can be easily coloured, so that the addition of UV resistant materials to the marking shell envelope is considered.
(3) Collision protection mechanisms. The large number of transformer plant equipment allows for the physical marking to be designed with a view to accelerating asset inventory and survey speed, taking into account impact-proof algorithms and achieving multiple identification batches, rapid and accurate reading in each work area.
3 Standard-setting for marking labelling
Physical marking labelling is the setting of clearly defined locations for each type of equipment, which will facilitate future installation, identification and reading. The electrical grid device specification should be developed taking into account outdoor equipment, interior equipment, characteristics of the unit equipment, handheld equipment and markings, and from a perspective, such as reading and writing distance, and the general principle must be based on practical application. Currently, RFID technology applications are largely free-of-source metal electronics, but it is not feasible to apply this type directly to an off-site power sensor, electropressor, or mine escaper. The use of handheld reading and writing devices at various voltage level transformers, both domestic and foreign, is tested to make it impossible to read identification information beyond 2 m. Therefore, the RFID labelling regulation is developed taking into account the existence of such factors.
4 Physical identification intermediates integrated with systems
The application of RFID technology can improve the efficiency of grid asset management, but the complexity of RFID's application of reading and writing equipment, the difficulty of integration with the grid company PMS system, SAP systems, the high inter-system convergence and poor adaptation to business changes. This makes companies cautious about implementing RFID technology, while the intermediate component helps RFID equipment integrate with network companies ERP systems and SAP.
Right now, R. of the grid company.FIDThe inter-message system is generally developed in a model based on SOA architecture, and the PAI interface provided by the RFID reading and writing device is integrated into the intermediate system through various means, such as IP address, port setting, etc., to facilitate the reading and writing of identification data for RFID devices, while combining collected data with the marking operation for effective filtering, processing and data transmission, and ultimately storing it in an intermediate database. The intermediate package also serves to monitor the RFID equipment and check the operation of RFID equipment. In addition, using RFID intermediates allows data interface and data exchange with systems such as ERP to be easily achieved.
Currently, the EMS is being used by grid enterprises to conduct outcome indicator evaluations. The system draws data mainly from PMS and SAP systems, but lacks information on physical data in situ, while physical identification is collected through RFID intermediates and on-site collection devices, which feed back physical information in time to the AMA decision-making system through interfaces, achieve a true sense of account, card, or material-compliant vertical closure, and provide more accurate asset operational status data for asset security management.
5 Physical identification data storage and data security requirements
Currently, ISO18000-6B standard electronic identifiers for the physical management of grid assets are standard mature, product stable, widely applied, global only ID number, multi-marked and read at the same time, store data of 1024b or 2048b capacity, with a data access speed of 40 kb/s. The amount of information stored in the physical identification takes into account the question of handheld equipment and back-office data exchange during on-site transport, where the major supplier is now basically equipped with GPS functions, but given the stability of communication transmission, there is no guarantee that intermediate system back-office data will be available at any time.
The storage of information on the content of the grid asset management marker is also considered. The contents of the memory storage bytes, which are sealed under ISO/IEC18000-6B protocols, are 206 bytes, while the content of the network equipment is stored in addition to the need for PMS systems to be connected with PM, AM and the need for relevant content. After many years of implementation, the information stored in the current version of the conversion station ' s marking content consists mainly of model, exit number, branding manufacturer, voltage level, the substation to which it belongs, date of shipment, state of equipment, type of identification, unit of measure, SAPID, SAP, material code, which allows for a more complete view of the basics and contents of the equipment.
6 Data transmission secure
The grid company uses a strict isolation approach to external mobile storage devices or mobile transmissions to protect against data risks, which prevents the timely uploading of handheld equipment capture information into intermediate systems, and likewise, the ease with which middle-system business documents can be uploaded to handheld terminals, but the multiple conversions that take place through secure disks. Because this is too cumbersome, it affects asset managers’ motivation in the use of RFID technology, so there is a need to address the root causes of equipment acquisition data transfer and security problems.
7 Particle Degrees
As the management of the safety of the assets of grid companies is well advanced, the network has been working on synchronization between PMS and SAP-PM module equipment, mainly for one time and secondary equipment. The synchronization work is only for major equipment, while ancillary equipment is not synchronized. Because of the high level of requirements for PMS system equipment type and certain fields maintenance as a result of the synchronization work, such as the inability of PMS system operators to synchronize with PM modules because they are not operationally skilled or responsible, it will affect the transfer and association with the finance AM module. Therefore, marking based on PMS data, although the most pellets and heavy work loads, can be used to check the simultaneous quality of PMS and PM in the marking process, as well as the quality of their connection with AM, which has a positive effect on improving the conformity rate for accounts (PM), cards (AM), and objects (RFID physical identification).
Summary
The RFID technology has been applied at different levels in the safety management of grid assets, and the technology is achieved by pasting physical identifiers on assets, storing equipment information without batch reading or data transmission. This will enable asset security management of equipment, through daily movement of physical identification data, dynamic tracking of equipment, removing difficulties in asset management, blind spots and barriers, and achieving accurate location management of asset equipment, whose application in the area of asset management would have very good prospects and would be efficient and cost-effective.
1 Collection Device Selection
The application of RFID to grid asset tracking management will allow for the use of handheld capture terminals (HDIs) for information gathering on physical markings on site, and because of their operation in an electromagnetic field environment, it is necessary to consider the anti-disruptiveness of end equipment, reading and writing distance, stability, reliability etc.
(1) Anti-disruptive factor. The electrical transformer is operating in an environment that produces a work frequency field and a work frequency magnetic field, where the work frequency magnetic field interference is low frequency sensor-based. Since the signal inside the handheld terminal does not use the earth as a reflow path, the electromagnetic protection design of the handheld terminal selection is considered for the handheld terminal design.
(2) Read-and-write distance. The physical marking of the grid is usually installed on a flat-train train that is located on the base of the equipment, and at certain altitude from the ground, so that operators can read and write data easily. Therefore, hand-held reading-and-writing distances are important to reduce the distance of asset inspectors, reduce their work intensity and increase the efficiency of the inspections.
(3) The handheld equipment is re-carrying. The substations above 220 kV are large in area, larger in equipment and long in duration of marking implementation, so that the handheld device batteries must have a longer re-defunct capacity and automatically save data after the power has been lost to ensure that staff members do not have concerns about their work on the site.
2 Physical marking performance
The RFID physical identifiers, which have the advantages of waterproofing, magnetic resistance, high temperature tolerance, long life expectancy, large distance reading, encryption of data, large amount of data storage, and modification of information storage, are widely applied to network asset tracking. Therefore, ISO18000-6B metal marking is used for asset tracking management. In outdoor and hot environments, electrical devices need to take due account of ultraviolet in design and material selection, reading-and-writing distances, multiple-mark reading, etc.
(1) Reading and writing distance. In the UHF electromagnetic environment of a power station, metal surfaces shield electromagnetic waves, which significantly deteriorate when the antenna inside signs is near the metal surface. After field application, markings are applied to the surface of a flat-wire train, signal failure is significant, reading and writing distances are reduced by 50% to 70%, so that the issue of reading and writing distance is taken into account in the design of the marking shell, the containment and the marking posting material.
(2) Anti-UV. Currently, UHF passive electronic sealing casings are commonly used as ABS material, and for the return of installed markings, electronic markings are long-lived in the wind of a power station and can be easily coloured, so that the addition of UV resistant materials to the marking shell envelope is considered.
(3) Collision protection mechanisms. The large number of transformer plant equipment allows for the physical marking to be designed with a view to accelerating asset inventory and survey speed, taking into account impact-proof algorithms and achieving multiple identification batches, rapid and accurate reading in each work area.
3 Standard-setting for marking labelling
Physical marking labelling is the setting of clearly defined locations for each type of equipment, which will facilitate future installation, identification and reading. The electrical grid device specification should be developed taking into account outdoor equipment, interior equipment, characteristics of the unit equipment, handheld equipment and markings, and from a perspective, such as reading and writing distance, and the general principle must be based on practical application. Currently, RFID technology applications are largely free-of-source metal electronics, but it is not feasible to apply this type directly to an off-site power sensor, electropressor, or mine escaper. The use of handheld reading and writing devices at various voltage level transformers, both domestic and foreign, is tested to make it impossible to read identification information beyond 2 m. Therefore, the RFID labelling regulation is developed taking into account the existence of such factors.
4 Physical identification intermediates integrated with systems
The application of RFID technology can improve the efficiency of grid asset management, but the complexity of RFID's application of reading and writing equipment, the difficulty of integration with the grid company PMS system, SAP systems, the high inter-system convergence and poor adaptation to business changes. This makes companies cautious about implementing RFID technology, while the intermediate component helps RFID equipment integrate with network companies ERP systems and SAP.
Right now, R. of the grid company.FIDThe inter-message system is generally developed in a model based on SOA architecture, and the PAI interface provided by the RFID reading and writing device is integrated into the intermediate system through various means, such as IP address, port setting, etc., to facilitate the reading and writing of identification data for RFID devices, while combining collected data with the marking operation for effective filtering, processing and data transmission, and ultimately storing it in an intermediate database. The intermediate package also serves to monitor the RFID equipment and check the operation of RFID equipment. In addition, using RFID intermediates allows data interface and data exchange with systems such as ERP to be easily achieved.
Currently, the EMS is being used by grid enterprises to conduct outcome indicator evaluations. The system draws data mainly from PMS and SAP systems, but lacks information on physical data in situ, while physical identification is collected through RFID intermediates and on-site collection devices, which feed back physical information in time to the AMA decision-making system through interfaces, achieve a true sense of account, card, or material-compliant vertical closure, and provide more accurate asset operational status data for asset security management.
5 Physical identification data storage and data security requirements
Currently, ISO18000-6B standard electronic identifiers for the physical management of grid assets are standard mature, product stable, widely applied, global only ID number, multi-marked and read at the same time, store data of 1024b or 2048b capacity, with a data access speed of 40 kb/s. The amount of information stored in the physical identification takes into account the question of handheld equipment and back-office data exchange during on-site transport, where the major supplier is now basically equipped with GPS functions, but given the stability of communication transmission, there is no guarantee that intermediate system back-office data will be available at any time.
The storage of information on the content of the grid asset management marker is also considered. The contents of the memory storage bytes, which are sealed under ISO/IEC18000-6B protocols, are 206 bytes, while the content of the network equipment is stored in addition to the need for PMS systems to be connected with PM, AM and the need for relevant content. After many years of implementation, the information stored in the current version of the conversion station ' s marking content consists mainly of model, exit number, branding manufacturer, voltage level, the substation to which it belongs, date of shipment, state of equipment, type of identification, unit of measure, SAPID, SAP, material code, which allows for a more complete view of the basics and contents of the equipment.
6 Data transmission secure
The grid company uses a strict isolation approach to external mobile storage devices or mobile transmissions to protect against data risks, which prevents the timely uploading of handheld equipment capture information into intermediate systems, and likewise, the ease with which middle-system business documents can be uploaded to handheld terminals, but the multiple conversions that take place through secure disks. Because this is too cumbersome, it affects asset managers’ motivation in the use of RFID technology, so there is a need to address the root causes of equipment acquisition data transfer and security problems.
7 Particle Degrees
As the management of the safety of the assets of grid companies is well advanced, the network has been working on synchronization between PMS and SAP-PM module equipment, mainly for one time and secondary equipment. The synchronization work is only for major equipment, while ancillary equipment is not synchronized. Because of the high level of requirements for PMS system equipment type and certain fields maintenance as a result of the synchronization work, such as the inability of PMS system operators to synchronize with PM modules because they are not operationally skilled or responsible, it will affect the transfer and association with the finance AM module. Therefore, marking based on PMS data, although the most pellets and heavy work loads, can be used to check the simultaneous quality of PMS and PM in the marking process, as well as the quality of their connection with AM, which has a positive effect on improving the conformity rate for accounts (PM), cards (AM), and objects (RFID physical identification).
Summary
The RFID technology has been applied at different levels in the safety management of grid assets, and the technology is achieved by pasting physical identifiers on assets, storing equipment information without batch reading or data transmission. This will enable asset security management of equipment, through daily movement of physical identification data, dynamic tracking of equipment, removing difficulties in asset management, blind spots and barriers, and achieving accurate location management of asset equipment, whose application in the area of asset management would have very good prospects and would be efficient and cost-effective.

Ms. Lei